Fluke 87V-MAX Handheld Digital Multimeter True RMS, 10 A, 10 A, 1 kV
- RS Stock No.:
- 194-6806
- Distrelec Article No.:
- 301-65-725
- Mfr. Part No.:
- FLUKE-87V-MAX
- Manufacturer:
- Fluke
- RS Stock No.:
- 194-6806
- Distrelec Article No.:
- 301-65-725
- Mfr. Part No.:
- FLUKE-87V-MAX
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Digital Multimeter | |
| Multimeter Type | Handheld | |
| Model Number | 87V-MAX | |
| Display Type | Digital | |
| Resistance Resolution | 100mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum Resistance Measurement | 0.05GΩ | |
| Maximum DC Current Measurement | 10A | |
| Maximum AC Voltage Measurement | 1kV | |
| Maximum DC Voltage Measurement | 1kV | |
| Maximum AC Current Measurement | 10A | |
| True RMS | Yes | |
| DC Current Accuracy | ±0.2 % rdg + 2 Digits | |
| AC Voltage Accuracy | ±0.7 % rdg + 4 Digits | |
| DC Voltage Accuracy | ±0.05 % rdg + 1 Digits | |
| AC Current Accuracy | ± 1 % rdg + 2 Digits | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| DC Current Resolution | 0.1μA dc | |
| AC Current Resolution | 0.1μA ac | |
| Maximum Frequency | 199.99kHz | |
| Power Source | Battery | |
| Minimum Operating Temperature | -15°C | |
| Resistance Measurement Accuracy | 0.2% + 1 | |
| Maximum Operating Temperature | +1090°C | |
| Battery Life | 800h | |
| Length | 198mm | |
| Height | 63.5mm | |
| Width | 101mm | |
| Weight | 698.5g | |
| Standards/Approvals | No | |
| Safety Category Level | CAT III, CAT IV | |
| Safety Category Voltage | 1kV | |
| Battery Type | AA | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Digital Multimeter | ||
Multimeter Type Handheld | ||
Model Number 87V-MAX | ||
Display Type Digital | ||
Resistance Resolution 100mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum Resistance Measurement 0.05GΩ | ||
Maximum DC Current Measurement 10A | ||
Maximum AC Voltage Measurement 1kV | ||
Maximum DC Voltage Measurement 1kV | ||
Maximum AC Current Measurement 10A | ||
True RMS Yes | ||
DC Current Accuracy ±0.2 % rdg + 2 Digits | ||
AC Voltage Accuracy ±0.7 % rdg + 4 Digits | ||
DC Voltage Accuracy ±0.05 % rdg + 1 Digits | ||
AC Current Accuracy ± 1 % rdg + 2 Digits | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
DC Current Resolution 0.1μA dc | ||
AC Current Resolution 0.1μA ac | ||
Maximum Frequency 199.99kHz | ||
Power Source Battery | ||
Minimum Operating Temperature -15°C | ||
Resistance Measurement Accuracy 0.2% + 1 | ||
Maximum Operating Temperature +1090°C | ||
Battery Life 800h | ||
Length 198mm | ||
Height 63.5mm | ||
Width 101mm | ||
Weight 698.5g | ||
Standards/Approvals No | ||
Safety Category Level CAT III, CAT IV | ||
Safety Category Voltage 1kV | ||
Battery Type AA | ||
- COO (Country of Origin):
- US
Fluke Digital Multimeter, 1000V Maximum DC Voltage Measurement, 10A Maximum DC Current Measurement - FLUKE-87V-MAX
Features and Benefits:
• DC voltage measurement with ±0.05% reading accuracy for precise diagnostics
• AC/DC current ranges up to 10A with 0.1μA resolution for fine current detection
• Frequency measurement to 199.99kHz for detailed signal analysis
• Resistance capability up to 0.05GΩ with 100mΩ resolution for component testing
• Battery life of 800 h enabling extended field operation without recharge
Applications
• Ideal for testing industrial control circuits in CAT III and CAT IV environments
• Used for maintenance of motors and inverters requiring frequency checks
• Can be used for component verification including capacitance and resistance
• Suitable for HVAC and refrigeration tasks requiring temperature measurement
What power source does it use and how long will it run?
What maximum voltages and safety categories are supported?
How does it perform on current measurements?
Which measurement ranges cover resistance and capacitance needs?
What environmental limits apply to its operation?
Contents
Related links
- Fluke 175 Handheld Digital Multimeter True RMS 10 A, 1 kV
- Fluke 179 Handheld Digital Multimeter True RMS 10 A, 1 kV
- Fluke 28EX Handheld Digital Multimeter True RMS 10 A, 1 kV
- Fluke 28 Handheld Digital Multimeter True RMS 10 A, 1 kV
- Fluke 87V 87V Handheld Multimeter True RMS 10 A, 1 kV
- Fluke 177 Handheld Digital Multimeter True RMS 10 A, 1 kV
- Fluke 113 Fluke 113 Handheld Digital Multimeter True RMS, 600 V ac
- Fluke 115 Handheld Digital Multimeter True RMS 10 A, 600 V