Recently searched

    Multifunction Testers

    Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements

    Multifunction Testers are integral to compliance with the 18th Edition of the Wiring Regulations (BS 7671). They enable electricians to meet the stringent testing requirements outlined in the 18th Edition, ensuring that electrical installations are safe, reliable, and in line with the latest industry standards. Additionally, MFTs often conform to other international standards, enhancing their credibility and usability in diverse global contexts.

    MFTs are ideal for testing a range of electrical parameters such as voltage, earth resistance, loop impedance and more. Many multifunction testers offer additional features such as Bluetooth, allowing you to store and transfer data from the device to a computer or mobile device. Here at RS, we have sourced multifunction test meters from leading brands such as Fluke, Megger, Gossen Metrawatt, RS PRO, and many more. You can learn more in our multifunction testers guide.

    What are Multifunction testers also known as?

    Multifunction Testers can be categorised with many different naming conventions, they are also commonly called Electrical Testers and Multifunction Installation Testers. However, even though they use slightly different names they all essentially do very similar things and due to their nature can be used in a range of different situations. It is important to check which tests the MFT can perform before you purchase one.

    Uses of Multifunction Testers

    Multifunction testers perform a variety of tests, including:

    • Insulation-continuity tests: Diagnose breakdown of the insulation in various parts of the electrical system such as wires, transformers, and motors. The quality of insulation is critical in ensuring uninterrupted and safe functioning of electrical circuits.
    • Checking RCD devices: Check the proper functioning of residual-current devices (RCDs). RCDs are designed to disconnect quickly to mitigate the harm caused by electric shock and to avoid current leaks that may lead to fire and other dangerous situations.
    • Loop testing: A quick, convenient, and specific method of evaluating an electrical circuit's ability to engage protective devices (circuit breakers, fuses, RCDs). A ground loop determines the effectiveness of protective devices.
    • Resistance measurement of grounding systems: Verification tests to ensure that a system's resistance is low enough to provide protection to people, equipment and structures.
    • Earth continuity tests

    Application

    Multifunction testers are used by electrical engineers for electrical installation work to verify and maintain electrical installations and that the required safety regulations have been reached in both commercial and industrial applications.

    What is the difference between multimeters (multi testers) and multifunction testers?

    They are both electronic measuring instruments. The multimeter measures basic electrical parameters such as voltage, current and resistance. A multifunction tester is tailored for comprehensive testing of electrical installations ensuring compliance with industry regulations and standards such as the Wiring Regulations (BS7671).

    29 Products showing for Multifunction Testers

    • RS Stock No. 477-808
    • Mfr. Part No. KT63DL
    Each
    MYR5,610.12
    Kewtech Corporation
    Automatic RCD Test,RCD Ramp Test,Non-Tripping
    -
    -
    KT63DL
    1000V
    -
    -
    -
    -
    -
    -
    -
    • RS Stock No. 477-796
    • Mfr. Part No. KT66DL
    Each
    MYR10,852.18
    Kewtech Corporation
    Automatic RCD Test,RCD Ramp Test,Non-Tripping
    -
    -
    KT66DL
    1000V
    -
    -
    -
    -
    -
    -
    -
    • RS Stock No. 231-1480
    • Mfr. Part No. P01145851
    Each
    MYR40,948.18
    Chauvin Arnoux
    -
    -
    -
    CA 6165
    1200V
    -
    -
    -
    -
    -
    -
    -
    Each
    MYR14,807.06
    Gossen Metrawatt
    RCD Ramp Test,Earth Resistance Measurement,Remote Switch Mode
    -
    Phase to Earth, Phase to Neutral
    Master Package PROFITEST INTRO
    3700V
    600V
    Wiring Polarity
    -
    15mA
    DC Selective
    IP40, IP52
    DIN VDE 0100-600, IEC 60364-6
    Each
    MYR6,186.82
    Martindale
    Automatic RCD Test,RCD Ramp Test,Non-Tripping,Earth Resistance Measurement
    -
    3 Wire, 4 Wire
    ET6000
    500V
    -
    -
    -
    -
    -
    -
    -
    • RS Stock No. 263-6765
    • Mfr. Part No. M513R
    Each
    MYR13,633.39
    Gossen Metrawatt
    RCD Ramp Test
    -
    -
    PROFITEST EMOBILITY
    -
    -
    -
    -
    -
    -
    -
    -
    Each
    MYR14,757.37
    Gossen Metrawatt
    RCD Ramp Test,Earth Resistance Measurement,Remote Switch Mode
    -
    Phase to Earth, Phase to Neutral
    Starter Package PROFITEST INTRO
    3700V
    600V
    Wiring Polarity
    -
    15mA
    DC Selective
    IP40, IP52
    DIN VDE 0100-600, IEC 60364-6
    • RS Stock No. 788-4580
    • Mfr. Part No. ET5
    Each
    MYR944.35
    Martindale
    -
    -
    -
    ET5
    -
    600V ac
    AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature
    -
    -
    -
    -
    -
    • RS Stock No. 292-1230
    • Mfr. Part No. Fluke T5-1000
    Each
    MYR1,429.00
    Fluke
    Automatic RCD Test
    -
    -
    T5
    -
    1000V ac
    AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
    -
    -
    -
    -
    -
    • RS Stock No. 788-4571
    • Mfr. Part No. ET4
    Each
    MYR844.43
    Martindale
    -
    -
    -
    ET4
    -
    600V ac
    -
    -
    -
    -
    -
    -
    • RS Stock No. 291-9372
    • Mfr. Part No. Fluke T5-600
    Each
    MYR1,123.00
    Fluke
    Automatic RCD Test
    -
    -
    T5
    -
    600V ac
    AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
    -
    -
    -
    -
    -
    Each
    MYR5,976.58
    Metrel
    Automatic RCD Test,Non-Tripping,Earth Resistance Measurement
    -
    3 Wire
    MI-3125
    -
    550V ac
    Continuity
    -
    -
    -
    IP40
    -
    Each
    MYR41,592.00
    Fluke
    Automatic RCD Test,Earth Resistance Measurement
    -
    -
    SMFT-1000
    1000V
    500V
    Continuity
    Wireless
    200mA
    -
    -
    IEC 62446-1
    Each
    MYR2,398.47
    Sefram
    Automatic RCD Test,Non-Tripping,Earth Resistance Measurement
    -
    Non Trip Earth Impedance
    MW9325
    190 → 265V
    -
    -
    -
    -
    -
    -
    -
    Each
    MYR30,793.26
    Gossen Metrawatt
    -
    -
    -
    M699B
    4 → 24V
    -
    -
    Bluetooth
    -
    -
    -
    -
    • RS Stock No. 263-6766
    • Mfr. Part No. M514R
    Each
    MYR7,952.81
    Gossen Metrawatt
    -
    -
    2 Wire, 2 Wire (Non-Trip Range), 3 Wire
    PROFITEST REMOTE
    300V
    -
    -
    -
    -
    -
    -
    -
    Each
    MYR13,364.55
    Fluke
    Automatic RCD Test,RCD Ramp Test,Earth Resistance Measurement,Downloadable Data,Remote Switch Mode
    -
    Phase to Earth, Phase to Neutral
    1664FC
    50 V, 100 V, 250 V, 500 V, 1000 V
    500V ac/dc
    Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Po
    BLE, USB
    10mA
    A/F, AC, B/B+, G, S
    IP40
    -
    • RS Stock No. 117-6665
    • Mfr. Part No. FLK-1662 SCH
    Each
    MYR10,170.00
    Fluke
    Automatic RCD Test,RCD Ramp Test,Remote Switch Mode
    -
    Phase to Earth, Phase to Neutral
    1662
    100 V, 250 V, 500 V, 1000 V
    500V ac/dc
    Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Po
    -
    10mA
    A/F, AC Type, G, S
    IP40
    IEC 60364
    • RS Stock No. 146-2607
    • Mfr. Part No. T6-600
    Each
    MYR1,698.00
    Fluke
    -
    -
    -
    T6-600
    -
    600V ac
    AC Current, AC Voltage, DC Voltage, Resistance
    -
    -
    -
    -
    -
    Each
    MYR12,880.27
    Fluke
    Automatic RCD Test,RCD Ramp Test,Earth Resistance Measurement
    -
    Phase to Earth, Phase to Neutral
    1664FC DE
    50 V, 100 V, 250 V, 500 V, 1000V
    500V
    -
    USB
    -
    AC, G, S
    IP40
    -
    Results per page