Druck DPI 620 25 mbar to 2 bar Pressure Calibrator Calibration Kit
- RS Stock No.:
- 199-3840
- Mfr. Part No.:
- DPI620PC-2barg
- Manufacturer:
- Druck
Subtotal (1 unit)*
MYR57,616.14
FREE delivery for orders over RM 150.00
Temporarily out of stock
- Shipping from 06 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | MYR57,616.14 |
*price indicative
- RS Stock No.:
- 199-3840
- Mfr. Part No.:
- DPI620PC-2barg
- Manufacturer:
- Druck
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Druck | |
| Maximum Pressure Measurement | 2bar | |
| Product Type | Pressure Calibrator Calibration Kit | |
| Battery Type | Lithium-Polymer | |
| Minimum Pressure Measurement | 25mbar | |
| Accuracy | ±0.005 % | |
| Pressure Port Type | Gauge | |
| Model Number | DPI 620 | |
| Data Logging | Yes | |
| Intrinsically Safe | No | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Power Source | Rechargeable lithium Battery | |
| Weight | 575g | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | BS EN 610101:2010, BS EN 613261:2006, CE | |
| Width | 114mm | |
| Length | 183mm | |
| Height | 42mm | |
| Hazardous Area Certification | ATEX, ETL, IECEx | |
| Plug Type | USB | |
| Select all | ||
|---|---|---|
Brand Druck | ||
Maximum Pressure Measurement 2bar | ||
Product Type Pressure Calibrator Calibration Kit | ||
Battery Type Lithium-Polymer | ||
Minimum Pressure Measurement 25mbar | ||
Accuracy ±0.005 % | ||
Pressure Port Type Gauge | ||
Model Number DPI 620 | ||
Data Logging Yes | ||
Intrinsically Safe No | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Power Source Rechargeable lithium Battery | ||
Weight 575g | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals BS EN 610101:2010, BS EN 613261:2006, CE | ||
Width 114mm | ||
Length 183mm | ||
Height 42mm | ||
Hazardous Area Certification ATEX, ETL, IECEx | ||
Plug Type USB | ||
- COO (Country of Origin):
- GB
Druck Pressure Calibrator Calibration Kit, 2 bar Maximum Pressure, ±0.005% Accuracy - DPI620PC-2barg
This pressure calibrator calibration kit provides precision pressure and loop current measurement for field and workshop use. It combines a gauge pressure port with an LCD for clear readouts and supports data logging for traceable results. The unit operates from a rechargeable lithium battery and is certified for hazardous locations, making it suitable for regulated industrial environments.
Features and Benefits:
• ±0.005% accuracy for precise comparators
• 25 mbar minimum pressure measurement for low-pressure checks
• Data-logging capability for traceable calibration records
• Rechargeable lithium‑polymer battery for extended field use
• ATEX, IECEx and ETL hazardous area certification for safe deployment
• 25 mbar minimum pressure measurement for low-pressure checks
• Data-logging capability for traceable calibration records
• Rechargeable lithium‑polymer battery for extended field use
• ATEX, IECEx and ETL hazardous area certification for safe deployment
Applications
• Suitable for calibrating instrumentation in hazardous areas
• Ideal for pressure transmitter validation and loop checks
• Used with gauge-mounted sensors for on-site verification
• Can be used for routine maintenance of control systems
• Suitable for commissioning tasks requiring logged measurements
• Ideal for pressure transmitter validation and loop checks
• Used with gauge-mounted sensors for on-site verification
• Can be used for routine maintenance of control systems
• Suitable for commissioning tasks requiring logged measurements
What temperature range can it operate within?
It functions between -10°C and 50°C.
How is the instrument connected for data transfer?
Data is exported via a USB plug.
What physical size and portability does it offer?
It has Compact dimensions of 183 x 114 x 42 mm and weighs 575 g.
Can it measure current loops as well as pressure?
Yes, it supports current loop measurement for combined testing.
Is the unit intrinsically safe for all hazardous zones?
It holds ATEX, IECEx and ETL certifications but is not intrinsically safe.
Note
Include DPI6020G-L unit in pack only, without HART.
Related links
- Druck DPI 620 25 mbar to 2 bar Pressure Calibrator Calibration Kit
- Druck DPI 620 25 mbar to 20 bar Pressure Calibrator Calibration Kit
- Druck DPI 620 25 mbar to 7 bar Pressure Calibrator Calibration Kit
- Druck DPI 800 25 mbar to 200 mbar Pressure Calibrator
- WIKA 48763673 Pressure Calibrator Calibration Kit, For Use With Portable Process Calibrator
- WIKA 83133683 Pressure Calibrator Calibration Kit, For Use With Portable Process Calibrator
- WIKA 48742321 Pressure Calibrator Calibration Kit, For Use With Hand Held Pressure Indicator
- WIKA 48804432 Pressure Calibrator Calibration Kit, For Use With Precision Hand-Held Pressure Indicator