Honeywell Technologies HDLS Series Roller Lever Limit Switch, SPDT, IP65, IP66, IP67, Die Cast Zinc Housing, 600V ac,
- RS Stock No.:
- 808-2873
- Mfr. Part No.:
- LSA1A-1A
- Manufacturer:
- Honeywell
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
- RS Stock No.:
- 808-2873
- Mfr. Part No.:
- LSA1A-1A
- Manufacturer:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Actuator Type | Roller Lever | |
| Product Type | Limit Switch | |
| IP Rating | IP65, IP66, IP67 | |
| Contact Configuration | SPDT | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Series | HDLS | |
| Switching AC Voltage | 600V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -12°C | |
| Maximum Operating Temperature | 121°C | |
| Width | 44.5mm | |
| Depth | 106.7mm | |
| Standards/Approvals | CCC, CE, CSA, EN, IEC, RoHS, UL | |
| Length | 41.1mm | |
| Hazardous Area Certification | No | |
| Mechanical Life | 50000000Cycles | |
| Conduit Entry | 12.7 mm | |
| Mounting Orientation | Side | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Actuator Type Roller Lever | ||
Product Type Limit Switch | ||
IP Rating IP65, IP66, IP67 | ||
Contact Configuration SPDT | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Series HDLS | ||
Switching AC Voltage 600V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -12°C | ||
Maximum Operating Temperature 121°C | ||
Width 44.5mm | ||
Depth 106.7mm | ||
Standards/Approvals CCC, CE, CSA, EN, IEC, RoHS, UL | ||
Length 41.1mm | ||
Hazardous Area Certification No | ||
Mechanical Life 50000000Cycles | ||
Conduit Entry 12.7 mm | ||
Mounting Orientation Side | ||
Honeywell HDLS Series Limit Switch, 10A switching current, 600V switching AC voltage - LSA1A-1A
This limit switch is a compact, side-mounted actuator device for detecting mechanical position changes in industrial systems. It uses a roller lever actuator and a snap-action contact arrangement to provide precise switching events in demanding environments. The enclosure is die-cast zinc with an epoxy finish and is rated for ingress protection in harsh conditions. Operating temperatures span low to high ranges to accommodate varied process requirements.
Features and Benefits:
• 50,000,000 cycle mechanical life gives long operational endurance
• SPDT snap-action contact provides distinct single-pole changeover switching
• 10A switching current supports moderate-load circuit control
• 250V DC switching capability enables DC control circuit use
• IP65, IP66, IP67 enclosure protects against dust and water ingress
• SPDT snap-action contact provides distinct single-pole changeover switching
• 10A switching current supports moderate-load circuit control
• 250V DC switching capability enables DC control circuit use
• IP65, IP66, IP67 enclosure protects against dust and water ingress
Applications
• Suitable for conveyor end-of-travel detection in factories
• Ideal for machine-tool limit sensing in production lines
• Used with motor starters for position-based shut-off
• Can be used for door-interlock status monitoring
• Ideal for machine-tool limit sensing in production lines
• Used with motor starters for position-based shut-off
• Can be used for door-interlock status monitoring
What actuator style does it use?
It employs a roller lever actuator for reliable mechanical engagement.
What material composes the housing?
The body is constructed from die-cast zinc with an epoxy coating.
What temperature range can it tolerate?
It operates between -12°C and 121°C.
Which approvals does it carry for industrial deployment?
It meets CCC, CE, CSA, EN, IEC, RoHS and UL standards.
How should it be mounted for correct operation?
It is designed for side-orientation mounting to align the roller lever with moving parts.
Approvals
UL, CSA.
Standards
IP65, IP66, IP67
HDLS switches have a IP65, IP66 and IP67 rating. This means they are dust-tight and offer protection against water jets, heavy seas and the effects of immersion.
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
Type 1: Enclosures that meet Type 1 are for indoor use, and provide some limited protection for the enclosed equipment.
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4X: Allows for indoor our outdoor use and provides some ptoection against windust dust and rain, corroision, splashing water and hose directed water.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 12: Limit switches that meet Type 12 requirements provide limited protection against dust, falling dirt and non-corrosive liquids.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as spraying splashing and seepage of oil and non-corrosive coolants."
HDLS switches have a IP65, IP66 and IP67 rating. This means they are dust-tight and offer protection against water jets, heavy seas and the effects of immersion.
NEMA 1, 3, 4, 4X, 6, 6P, 12, 13
Type 1: Enclosures that meet Type 1 are for indoor use, and provide some limited protection for the enclosed equipment.
Type 3: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as windblown dust) and the ingress of water (such as rain or snow). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 3 offer protection against ice forming externally.
Type 4X: Allows for indoor our outdoor use and provides some ptoection against windust dust and rain, corroision, splashing water and hose directed water.
Type 6: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from foreign objects (such as falling dirt and windblown dust) and the ingress of water (such as rain, snow or sleet alongside splashing water and hose directed water). Enclosures that meet NEMA 4 offer protection against ice forming externally.
Type 6P: Allows for indoor or outdoor use and provides a degree of protection against access to hazardous parts. The enclosures provide some protection from solid objects (such as falling dirt and windblown dust) and the ingress of water (such as hose directed water). Enclosures that meet the NEMA 6P requirement also offer protection against water when being submerged at a limited depth.
Type 12: Limit switches that meet Type 12 requirements provide limited protection against dust, falling dirt and non-corrosive liquids.
Type 13: Enclosures that meet Type 13 are suited to harsh environments. Enclosures can be used indoors and provide protection against access to hazardous parts. They offer protection against solid objects such as falling dirt, windblown dirt, fibres and lint. They provide a level of protection from dripping and splashing water and other liquids such as spraying splashing and seepage of oil and non-corrosive coolants."
Related links
- Honeywell Technologies HDLS Series Plunger Limit Switch IP65 IP67 600V
- Honeywell Technologies HDLS Series Side Rotary Limit Switch IP67 600V
- Honeywell Technologies HDLS Series Side Rotary Limit Switch IP65 IP67 600V ac
- Honeywell Technologies HDLS Series Roller Lever Limit Switch IP67 600V
- Honeywell Technologies HDLS Series Coil Spring Limit Switch IP65 IP67
- Honeywell Technologies HDLS Series Roller Lever Limit Switch IP67 240V ac,
- Honeywell Technologies HDLS Series Side Rotary Limit Switch IP65 IP66 600V ac, 10A
- Honeywell Technologies HDLS Series Roller Lever Actuator IP67 IP65 600V ac
