SICK C2MT Series Light Curtain Receiver, Sender, 24 mm Resolution

Subtotal (1 unit)*

MYR3,981.71

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later
Units
Per Unit
1 +MYR3,981.71

*price indicative

RS Stock No.:
701-2937
Mfr. Part No.:
C2MT-06024BBC04FE0
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Light Curtain

Series

C2MT

Beam Resolution

24mm

Component Type

Receiver, Sender

Safety Type

Type 2

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

600mm

Maximum Supply Voltage

24V dc

Maximum Protective Width

8m

Minimum Scanning Distance

0μm

Maximum Scanning Distance

8m

Maximum Response Time

13ms

Width

15mm

Height

600mm

Length

32mm

Terminal Type

5-Pin M12

COO (Country of Origin):
DE

SICK C2MT Series Light Curtain, 600mm Protective Height, 24V DC Supply Voltage - C2MT-06024BBC04FE0


This light curtain provides non-contact presence detection for machine safeguarding and access protection in industrial environments. It operates as a receiver in a twin-stick configuration with optical synchronisation and is supplied with mounting brackets, a system plug and a test rod. The device functions as a standalone safety sensor with built-in LEDs for status indication and hard-wired configuration for straightforward integration into safety circuits.

Features and Benefits:


• 13ms maximum response time ensuring Rapid hazard detection
• 24mm beam resolution reducing undetected intrusion risk
• 8m maximum protective width enabling wide-area coverage
• Type2 safety classification supporting category 2 system designs
• M12 5-pin Terminal for simple 24V DC connection

Applications


• Suitable for safeguarding moving machine guards and doors
• Used with production lines requiring short detection distances
• Ideal for integration into safety relay control architectures
• Suitable for packaging machinery access protection
• Used for perimeter protection on material handling systems

What electrical connection does it use?


It connects via a 5-pin M12 plug and operates from 24V DC.

How is synchronisation achieved between sticks?


Synchronisation is optical and does not require separate wiring.

What environmental conditions can it withstand?


It has IP65 protection, operates between -20°C and +55°C and tolerates 15%-95% non-condensing humidity.

What fault behaviour is provided on failure?


In the event of a fault at least one OSSD is switched to the OFF state.

What mechanical form factor should be considered for mounting?


The housing measures 15mm x 32mm cross-section and includes O-fix brackets for installation.

Note

Two identical miniTwin-stick packages MUST always be ordered for a complete system.,Cable: Each miniTwin is supplied with an M12 5-pin 1-way system plug. To cascade 3 pairs you will need 2 x cascade cables. Either 701-2962 for miniTwin up to 540mm or 701-2971 for miniTwin over 600mm. These cascade cables have 2 x plugs and should be attached to the rear of your middle pair of miniTwin. The cascade extender cable 701-2974 can be used in conjunction with the 2 x cascade cables to increase the distance between miniTwin if required. Regardless of whether you use these devices stand-alone or in a 2 x pair or cascade format you will need to purchase 2 x M12 5-pin connector cable eg 523-0335.,Brackets: 2 x C-Fix and 2 x L-Fix brackets are supplied with each miniTwin. To mount (stand-alone only) as a flat installation on a profile frame or in a machine niche purchase optional O-Fix brackets 701-2978

Related links