Omron H3DT Series DIN Rail Timer, 2-Contact, 240 V dc 200V ac, 240 V ac, 1 to 120 s, 1-Function, SPDT Switch
- RS Stock No.:
- 106-6247
- Mfr. Part No.:
- H3DT-HDL 200-240VAC
- Manufacturer:
- Omron
Subtotal (1 unit)*
MYR594.88
FREE delivery for orders over RM 500.00
In Stock
- Plus 1 unit(s) shipping from 13 July 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | MYR594.88 |
*price indicative
- RS Stock No.:
- 106-6247
- Mfr. Part No.:
- H3DT-HDL 200-240VAC
- Manufacturer:
- Omron
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Omron | |
| Product Type | Timer | |
| Function | Offset Double Ring End, Timer | |
| Mount Type | DIN Rail | |
| Time Range | 1 to 120 s | |
| Number of Contacts | 2 | |
| Switching Voltage | 250V ac | |
| Number of Timer Functions | 1 | |
| Contact Configuration | SPDT | |
| IP Rating | IP30, IP20 | |
| Contact Current | 5A | |
| Supply DC Voltage | 240 V dc | |
| Supply AC Voltage | 200, 240V ac | |
| Minimum Operating Temperature | -20°C | |
| Terminal Type | Push-in | |
| Maximum Operating Temperature | 60°C | |
| Length | 17.5mm | |
| Width | 90mm | |
| Standards/Approvals | cULus:UL 508/CSA C22.2 No. 14, CCC, EN 61812-1, DNV GL, RoHS, IEC 60664-1 4 kV/2, LR | |
| Height | 100mm | |
| Series | H3DT | |
| Select all | ||
|---|---|---|
Brand Omron | ||
Product Type Timer | ||
Function Offset Double Ring End, Timer | ||
Mount Type DIN Rail | ||
Time Range 1 to 120 s | ||
Number of Contacts 2 | ||
Switching Voltage 250V ac | ||
Number of Timer Functions 1 | ||
Contact Configuration SPDT | ||
IP Rating IP30, IP20 | ||
Contact Current 5A | ||
Supply DC Voltage 240 V dc | ||
Supply AC Voltage 200, 240V ac | ||
Minimum Operating Temperature -20°C | ||
Terminal Type Push-in | ||
Maximum Operating Temperature 60°C | ||
Length 17.5mm | ||
Width 90mm | ||
Standards/Approvals cULus:UL 508/CSA C22.2 No. 14, CCC, EN 61812-1, DNV GL, RoHS, IEC 60664-1 4 kV/2, LR | ||
Height 100mm | ||
Series H3DT | ||
- COO (Country of Origin):
- CN
Omron H3DT Series Timer, 1 to 120s Time Range, 200V AC Supply Voltage - H3DT-HDL 200-240VAC
This timer provides adjustable time-delay switching for industrial control panels and automation systems, enabling delayed or timed changeover between circuits in electromechanical installations. It operates from AC or DC supplies and is designed for DIN-rail mounting in cabinet environments where Compact timing control and straightforward wiring are required.
Features and Benefits:
• Time range 1-120 s delivers flexible delay settings for diverse processes
• SPDT contacts rated 5 A provide dependable single-pole switching capability
• Accepts 200 VAC, 240 VAC and 240 VDC supplies for wide compatibility
• Push-in terminals enable rapid, tool-free connection and maintenance
• Switching voltage up to 250 VAC allows integration with AC control circuits
• Two-contact configuration supports Basic changeover and signalling tasks
• SPDT contacts rated 5 A provide dependable single-pole switching capability
• Accepts 200 VAC, 240 VAC and 240 VDC supplies for wide compatibility
• Push-in terminals enable rapid, tool-free connection and maintenance
• Switching voltage up to 250 VAC allows integration with AC control circuits
• Two-contact configuration supports Basic changeover and signalling tasks
Applications
• Suitable for sequencing motors and conveyor start-up delays
• Ideal for interlocking contactor control in panel installations
• Used for timed control of valves and solenoid actuation
• Can be used for delayed alarm or indicator activation
• Used with PLC systems as a Compact timing auxiliary relay
• Ideal for interlocking contactor control in panel installations
• Used for timed control of valves and solenoid actuation
• Can be used for delayed alarm or indicator activation
• Used with PLC systems as a Compact timing auxiliary relay
What mounting method is required for installation?
It clips directly onto a standard DIN rail to SIT alongside other control devices.
How does it handle different ambient conditions?
It is specified to operate between -20 °C and 60 °C to suit a range of indoor cabinet temperatures.
What contact arrangement and quantity are provided?
There are two changeover contacts in a single SPDT arrangement to switch one circuit while providing a complementary contact.
What ingress protection is offered for panel-mounted use?
The unit carries IP ratings appropriate for interior control-panel environments, providing Basic protection for internal wiring.
Which Terminal style simplifies field wiring?
The device uses push-in style terminals designed for quick insertion of conductors without screw tightening.
Related links
- Omron H3DT Series DIN Rail Timer Relay 240 V dc 200V ac 1 to 120 s SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 240 V dc 24V ac 0.1 s to 1200 h SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 24 to 240 V 24V ac 1 to 120 s SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 240 V 100V ac 1 to 120 s SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 240 V dc 100V ac 1 to 120 s SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 240 V dc 24 V 1 to 120 s SPDT Switch
- Omron H3DT Series DIN Rail Solid State Timer 240 V dc 48V ac 1-Function, SPDT Switch
- Omron H3DT Series DIN Rail Timer Relay 240 V dc 24V ac 0.1 s to 1200 h DPDT Switch