Finder Series 39 Series Solid State Interface Relay, 13.2 V Control, 6 A Load, DIN Rail Mount
- RS Stock No.:
- 819-8795
- Mfr. Part No.:
- 39.00.7.012.9024
- Manufacturer:
- Finder
Subtotal (1 unit)*
MYR255.98
FREE delivery for orders over RM 500.00
In Stock
- 3 unit(s) ready to ship from another location
- Plus 5 unit(s) shipping from 19 December 2025
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | MYR255.98 |
*price indicative
- RS Stock No.:
- 819-8795
- Mfr. Part No.:
- 39.00.7.012.9024
- Manufacturer:
- Finder
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Finder | |
| Maximum Control Voltage | 13.2 V | |
| Maximum Load Current | 6 A | |
| Mounting Type | DIN Rail | |
| Maximum Load Voltage | 24 V dc | |
| Minimum Control Voltage | 9.6 V | |
| Control Voltage Range | 9.6 → 13.2 V | |
| Switching Type | DC | |
| Contact Configuration | SPST | |
| Load Voltage Range | 1..5 → 33V dc | |
| Minimum Load Voltage | 1.5 V dc | |
| Terminal Type | Push In | |
| Number of Poles | 1 | |
| Output Device | PLC | |
| Series | Series 39 | |
| Minimum Load Current | 1 mA | |
| Minimum Operating Temperature | -20°C | |
| Off State Leakage Current | 0.001 mA | |
| Standards Met | cURus, EAC | |
| Maximum Operating Temperature | +70°C | |
| Maximum Turn On Time | 0.2 ms | |
| Manufacturer Part No. | 39.00.7.012.9024 | |
| Operating Temperature Range | -20 → +70°C | |
| Select all | ||
|---|---|---|
Brand Finder | ||
Maximum Control Voltage 13.2 V | ||
Maximum Load Current 6 A | ||
Mounting Type DIN Rail | ||
Maximum Load Voltage 24 V dc | ||
Minimum Control Voltage 9.6 V | ||
Control Voltage Range 9.6 → 13.2 V | ||
Switching Type DC | ||
Contact Configuration SPST | ||
Load Voltage Range 1..5 → 33V dc | ||
Minimum Load Voltage 1.5 V dc | ||
Terminal Type Push In | ||
Number of Poles 1 | ||
Output Device PLC | ||
Series Series 39 | ||
Minimum Load Current 1 mA | ||
Minimum Operating Temperature -20°C | ||
Off State Leakage Current 0.001 mA | ||
Standards Met cURus, EAC | ||
Maximum Operating Temperature +70°C | ||
Maximum Turn On Time 0.2 ms | ||
Manufacturer Part No. 39.00.7.012.9024 | ||
Operating Temperature Range -20 → +70°C | ||
- COO (Country of Origin):
- IT
Finder Series 39 Series Solid State Interface Relay, 6A Load Current, 24V Maximum Load Voltage - 39.00.7.012.9024
This solid state interface relay is designed for efficient control and operation within electrical systems. Manufactured by Finder, this DC relay is well-suited for use on DIN rails, providing a compact solution for automation and control tasks. The relay features an operational voltage range from 9.6V to 13.2V and supports a maximum load current of 6A, making it a versatile choice for various applications in the electrical and mechanical sectors.
Features & Benefits
• Offers a control voltage range of 9.6V to 13.2V for flexibility
• Maximum load voltage of 24V DC suitable for diverse applications
• SPST configuration allows for simple switching solutions
• Push-in terminal type ensures ease of wiring and installation
• Fast turn-on time of just 0.2 ms enhances operational efficiency
• Designed to operate within a temperature range of -20°C to +70°C for reliability
• Maximum load voltage of 24V DC suitable for diverse applications
• SPST configuration allows for simple switching solutions
• Push-in terminal type ensures ease of wiring and installation
• Fast turn-on time of just 0.2 ms enhances operational efficiency
• Designed to operate within a temperature range of -20°C to +70°C for reliability
Applications
• Ideal for controlling standard PLC output devices
• Utilised in industrial automation systems for seamless control
• Used in requiring reliable switching of DC loads
• Suitable for equipment that operates on a DIN rail for simplified mounting
• Utilised in industrial automation systems for seamless control
• Used in requiring reliable switching of DC loads
• Suitable for equipment that operates on a DIN rail for simplified mounting
What is the significance of the maximum load current rating?
The maximum load current rating of 6 A indicates the highest current the relay can handle without damage, ensuring safe and reliable operation when used within specified limits.
How does the switching type affect performance in real-world applications?
The DC switching type allows for effective control in applications utilising direct current loads, enhancing the relay's compatibility with a variety of systems.
What advantages does a push-in terminal type offer during installation?
A push-in terminal type simplifies the wiring process, reducing installation time and improving connection reliability by providing secure connections without the need for additional tools.
What are the implications of the off-state leakage current value?
With an off-state leakage current of just 0.001 mA, it indicates minimal energy loss in standby mode, which is beneficial for energy efficiency in circuit designs.
How does the operational temperature range affect its application?
The broad operational temperature range of -20°C to +70°C ensures that the relay remains functional and reliable under varying environmental conditions, making it suitable for use in diverse settings.