Schneider Electric Residual Current Circuit Breaker with Overload Protection, 10 A Current Rating, 2-Pole, 30 mA Trip
- RS Stock No.:
- 428-816
- Mfr. Part No.:
- A9D27210
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
MYR5,323.33
FREE delivery for orders over RM 500.00
Temporarily out of stock
- Shipping from 02 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | MYR5,323.33 |
*price indicative
- RS Stock No.:
- 428-816
- Mfr. Part No.:
- A9D27210
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 10 A | |
| Series | Acti9 iC60 RCBO | |
| Range | Acti9 | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Terminal Type | Tunnel | |
| Height | 86mm | |
| Width | 36 mm | |
| Depth | 78mm | |
| Application | Distribution | |
| Tripping Mechanism | Thermal Magnetic | |
| Standards/Approvals | IEC 610091, IEC 60947 EN, EN | |
| Breaking Capacity | 10000A | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 10 A | ||
Series Acti9 iC60 RCBO | ||
Range Acti9 | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Terminal Type Tunnel | ||
Height 86mm | ||
Width 36 mm | ||
Depth 78mm | ||
Application Distribution | ||
Tripping Mechanism Thermal Magnetic | ||
Standards/Approvals IEC 610091, IEC 60947 EN, EN | ||
Breaking Capacity 10000A | ||
- COO (Country of Origin):
- PT
The Schneider Electric Acti9 iC60 RCBO is a modular residual current device with overcurrent protection. It is a 2P RCBO with 2 protected poles, a rated current of 10A and an operating voltage of 220VAC to 240VAC. The earth leakage protection class is A-SI with a sensitivity of 30mA. The earth leakage protection delay is instantaneous. The breaking capacity at 220VAC to 240VAC is 10000A according to EN/IEC 61009-2-1. The breaking capacity at 220VAC to 240VAC is 15kA according to EN/IEC 60947-2. Its unique Visitrip indicator reduces intervention time by indicating the faulty circuit.
IP20 and IP40 protection rated
Mercury free
RoHS compliant
Overvoltage III category conforming to IEC 60364
Related links
- Schneider Electric RCBO 2P Poles Type AC, Acti9 Range
- Schneider Electric RCBO 1P Poles Type C, Acti9 Range
- Schneider Electric RCBO 4P Poles Type C, Acti9 Range
- Schneider Electric RCBO 1P+N Poles Type C, Acti9 Range
- Schneider Electric RCBO 2P Poles Type C, Acti9 Range
- Schneider Electric RCBO 2P Poles Type C, Acti9 Range
- Schneider Electric RCBO 2P Poles Type C, Acti9 Range
- Schneider Electric RCBO 2P Poles Type C, Acti9 Range