Fluke G 1/4 RS232 Pressure Gauge, 114 mm, 200 bar
- RS Stock No.:
- 758-8917
- Distrelec Article No.:
- 176-50-056
- Mfr. Part No.:
- Fluke-700G29
- Manufacturer:
- Fluke
This image is representative of the product range
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
- RS Stock No.:
- 758-8917
- Distrelec Article No.:
- 176-50-056
- Mfr. Part No.:
- Fluke-700G29
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Pressure Gauge | |
| Maximum Pressure Measurement | 200bar | |
| Minimum Pressure Measurement | -0.97bar | |
| Pressure Connection | 1/4 inch NPT Male | |
| Connection Size | G 1/4 | |
| Accuracy | ±0.05 % | |
| Connection Type | 1/4 in NPT Male | |
| Series | Fluke 700G | |
| Interface Type | RS232 | |
| Case Material | Aluminium, Cast Zinc | |
| Connection Location | Digital | |
| Minimum Operating Temperature | -10°C | |
| Number of Display Digits | 5.5 | |
| Dial Size | 114mm | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | CSA | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Pressure Gauge | ||
Maximum Pressure Measurement 200bar | ||
Minimum Pressure Measurement -0.97bar | ||
Pressure Connection 1/4 inch NPT Male | ||
Connection Size G 1/4 | ||
Accuracy ±0.05 % | ||
Connection Type 1/4 in NPT Male | ||
Series Fluke 700G | ||
Interface Type RS232 | ||
Case Material Aluminium, Cast Zinc | ||
Connection Location Digital | ||
Minimum Operating Temperature -10°C | ||
Number of Display Digits 5.5 | ||
Dial Size 114mm | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals CSA | ||
RoHS Status: Exempt
Fluke 700G Series Pressure Gauge, 114mm Dial Size, 200 Bar Maximum Pressure Measurement - Fluke-700G29
This pressure gauge is a precision instrument for measuring pressures from vacuum to high pressure in industrial settings. It provides a digital readout and rugged construction suitable for field and workshop use, with a 114mm dial and connections compatible with 1/4 in NPT male fittings. The unit is supplied calibrated and housed in aluminium and cast zinc to withstand typical service environments.
Features & Benefits
• Accuracy ±0.05% of full scale for precise readings
• Range from −0.97 to 200 bar for broad measurement coverage
• G 1/4 connection location for straightforward installation
• 1/4 in NPT male pressure connection for common fittings
• CSA approval for use in hazardous-area classifications
• Digital display with 5½ digits and 20-segment bar graph
• Range from −0.97 to 200 bar for broad measurement coverage
• G 1/4 connection location for straightforward installation
• 1/4 in NPT male pressure connection for common fittings
• CSA approval for use in hazardous-area classifications
• Digital display with 5½ digits and 20-segment bar graph
**Applications**
• Suitable for calibration benches requiring high-accuracy pressure measurement
• Ideal for hydraulic system testing up to 200 bar
• Used for pneumatic leak detection and vacuum checks
• Can be used with handheld test pumps for on-site verification
• Used with data-logging software for remote measurement capture
• Ideal for hydraulic system testing up to 200 bar
• Used for pneumatic leak detection and vacuum checks
• Can be used with handheld test pumps for on-site verification
• Used with data-logging software for remote measurement capture
What media compatibility should I consider for field use?
Use any clean, dry, non-corrosive gas for very low ranges
for ranges up to 1000 psi use liquids or gases compatible with 316 stainless steel
above 1000 psi choose non-flammable, non-toxic, non-explosive, non-oxidising fluids compatible with 316 stainless steel.
How is data logging achieved with this device?
Logged measurements can be stored internally and transferred to a PC using dedicated logging software and a communication cable to configure, download and export recorded events.
What are the operating temperature limits for rated accuracy?
The unit is temperature compensated between 0 °C and 50 °C
outside that window, down to −10 °C or up to 55 °C, add a specified accuracy correction per °C.
What accessories are provided to aid installation and verification?
Supplied items include a manual on CD-ROM in multiple languages, a traceable calibration certificate and a 1/4˝ NPT to 1/4˝ ISO adapter.
Note
The 700G gauges can be combined with the 7588920 (700PTPK) or 7588926 (700HTPK) pump kits, available separately, for a complete pressure testing solution for up to 600psi with the PTP-1 pneumatic pump and up to 10,000psi with the HTP-2 hydraulic pump. Up to 8493 pressure measurements can be logged to memory using 7588923 700G/TRACK logging software (available separately).
Approvals
CSA, ATEX
Related links
- Fluke G 1/4 RS232 Pressure Gauge 340 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 20 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 34 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 6.9 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 690 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 140 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 2 bar Calibrated
- Fluke G 1/4 RS232 Pressure Gauge 69 bar Calibrated