Belden, 500 m Cat6a Cat6A Cable, Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, F/FTP

Currently unavailable
Sorry, we don't know when this will be back in stock.
RS Stock No.:
631-593
Mfr. Part No.:
10GXE01.07500
Manufacturer:
Belden
Find similar products by selecting one or more attributes.
Select all

Brand

Belden

Product Type

Cat6A Cable

Cable Length

500m

LAN Category

Cat6a

Shield Type

F/FTP

Connector Type A

Straight

Connector Type B

Unterminated

Jacket Colour

Purple

Jacket Material

Low Smoke Zero Halogen

Standards/Approvals

CE, EU, ISO/IEC 11801-1, IEC 62821

Series

10GXE01

Voltage

72V

COO (Country of Origin):
HU

Belden Power Cable Assembly, 500m Cable Length, Purple Jacket - 10GXE01.07500


This power cable assembly provides a long-reach, shielded supply solution for industrial and telecom installations where extended, low-emission cabling is required. It is supplied as a continuous, unterminated run in a highly visible purple jacket suitable for environments that need reduced toxic fume output. The construction supports medium-voltage distribution up to 72V and meets recognised international and regional standards for structured cabling and electrical installation.

Features & Benefits


• 500m length enables extended single-run installations
• F/FTP shielding reduces electromagnetic interference for sensitive equipment
• Low Smoke Zero Halogen jacket limits toxic emissions during combustion
• Purple sheath offers quick Visual identification in cable routes
• Conforms to EU and CE requirements for regional deployment

**Applications**


• Suitable for telecom room link cabling requiring shielded runs
• Ideal for data centre power routing with low-smoke requirements
• Used for factory automation where interference suppression is needed
• Can be used for electrical installations in public buildings with strict emission rules

How is the cable delivered for on-site termination?


It is supplied unterminated so technicians can perform bespoke connectorisation and length-specific preparations on site.

Which shielding arrangement is used to protect conductors?


The construction uses foil with individually screened pairs to provide comprehensive pair-level and overall screening.

What does the jacket material offer compared with standard PVC?


The jacket material is formulated to produce minimal smoke and no halogen acids if exposed to fire, improving occupant safety and equipment protection.

Which standards does the cable align with for structured cabling and safety?


It meets applicable international structured cabling and electrical installation standards specified for EU and global use.

Related links