Belden, 500 m Cat6a Cat6A Cable, Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, F/FTP
- RS Stock No.:
- 631-593
- Mfr. Part No.:
- 10GXE01.07500
- Manufacturer:
- Belden
Currently unavailable
Sorry, we don't know when this will be back in stock.
- RS Stock No.:
- 631-593
- Mfr. Part No.:
- 10GXE01.07500
- Manufacturer:
- Belden
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Belden | |
| Product Type | Cat6A Cable | |
| Cable Length | 500m | |
| LAN Category | Cat6a | |
| Shield Type | F/FTP | |
| Connector Type A | Straight | |
| Connector Type B | Unterminated | |
| Jacket Colour | Purple | |
| Jacket Material | Low Smoke Zero Halogen | |
| Standards/Approvals | CE, EU, ISO/IEC 11801-1, IEC 62821 | |
| Series | 10GXE01 | |
| Voltage | 72V | |
| Select all | ||
|---|---|---|
Brand Belden | ||
Product Type Cat6A Cable | ||
Cable Length 500m | ||
LAN Category Cat6a | ||
Shield Type F/FTP | ||
Connector Type A Straight | ||
Connector Type B Unterminated | ||
Jacket Colour Purple | ||
Jacket Material Low Smoke Zero Halogen | ||
Standards/Approvals CE, EU, ISO/IEC 11801-1, IEC 62821 | ||
Series 10GXE01 | ||
Voltage 72V | ||
- COO (Country of Origin):
- HU
Belden Power Cable Assembly, 500m Cable Length, Purple Jacket - 10GXE01.07500
This power cable assembly provides a long-reach, shielded supply solution for industrial and telecom installations where extended, low-emission cabling is required. It is supplied as a continuous, unterminated run in a highly visible purple jacket suitable for environments that need reduced toxic fume output. The construction supports medium-voltage distribution up to 72V and meets recognised international and regional standards for structured cabling and electrical installation.
Features & Benefits
• 500m length enables extended single-run installations
• F/FTP shielding reduces electromagnetic interference for sensitive equipment
• Low Smoke Zero Halogen jacket limits toxic emissions during combustion
• Purple sheath offers quick Visual identification in cable routes
• Conforms to EU and CE requirements for regional deployment
• F/FTP shielding reduces electromagnetic interference for sensitive equipment
• Low Smoke Zero Halogen jacket limits toxic emissions during combustion
• Purple sheath offers quick Visual identification in cable routes
• Conforms to EU and CE requirements for regional deployment
**Applications**
• Suitable for telecom room link cabling requiring shielded runs
• Ideal for data centre power routing with low-smoke requirements
• Used for factory automation where interference suppression is needed
• Can be used for electrical installations in public buildings with strict emission rules
• Ideal for data centre power routing with low-smoke requirements
• Used for factory automation where interference suppression is needed
• Can be used for electrical installations in public buildings with strict emission rules
How is the cable delivered for on-site termination?
It is supplied unterminated so technicians can perform bespoke connectorisation and length-specific preparations on site.
Which shielding arrangement is used to protect conductors?
The construction uses foil with individually screened pairs to provide comprehensive pair-level and overall screening.
What does the jacket material offer compared with standard PVC?
The jacket material is formulated to produce minimal smoke and no halogen acids if exposed to fire, improving occupant safety and equipment protection.
Which standards does the cable align with for structured cabling and safety?
It meets applicable international structured cabling and electrical installation standards specified for EU and global use.
Related links
- Belden Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Purple Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
- Belden Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, F/FTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Yellow Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Black Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Blue Straight to Unterminated Low Smoke Zero Halogen Sheath, F/UTP
- Belden Grey Straight to Unterminated Low Smoke Zero Halogen Sheath, S/FTP
