Recom REM3 DC-DC Converter, 5V dc/ 600mA Output, 18 → 36 V dc Input, 3W, Through Hole, +105°C Max Temp -40°C Min
- RS Stock No.:
- 166-6503
- Mfr. Part No.:
- REM3-2405S/A
- Manufacturer:
- Recom
Subtotal (1 tube of 7 units)**
MYR2,045.53
* Delivery dates may change based on your chosen quantity and delivery address.
FREE delivery for orders over MYR700.00
Tube(s) | Per Tube | Per Unit** |
---|---|---|
1 - 1 | MYR2,045.53 | MYR292.219 |
2 - 3 | MYR2,000.53 | MYR285.79 |
4 + | MYR1,957.57 | MYR279.653 |
**price indicative
- RS Stock No.:
- 166-6503
- Mfr. Part No.:
- REM3-2405S/A
- Manufacturer:
- Recom
Select all | Attribute | Value |
---|---|---|
Manufacturer | Recom | |
Output Voltage | 5V dc | |
Input Voltage Range | 18 → 36 V dc | |
Power Rating | 3W | |
Input Voltage Nominal | 24 V dc | |
Output Current | 600mA | |
Mounting Type | Through Hole | |
Isolated | Yes | |
Number of Outputs | 1 | |
Output Voltage Adjustment Range | ±10% | |
Package | DIP 24 | |
Isolation Voltage | 5kV ac | |
Width | 20.3mm | |
Depth | 10.4mm | |
Length | 31.8mm | |
Series | REM3 | |
Load Regulation | ±0.2% | |
Maximum Temperature | +105°C | |
Efficiency | 84 %, 84.5 % | |
Standards Met | ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A11, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A11, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | |
Minimum Temperature | -40°C | |
Select all | ||
---|---|---|
Manufacturer Recom | ||
Output Voltage 5V dc | ||
Input Voltage Range 18 → 36 V dc | ||
Power Rating 3W | ||
Input Voltage Nominal 24 V dc | ||
Output Current 600mA | ||
Mounting Type Through Hole | ||
Isolated Yes | ||
Number of Outputs 1 | ||
Output Voltage Adjustment Range ±10% | ||
Package DIP 24 | ||
Isolation Voltage 5kV ac | ||
Width 20.3mm | ||
Depth 10.4mm | ||
Length 31.8mm | ||
Series REM3 | ||
Load Regulation ±0.2% | ||
Maximum Temperature +105°C | ||
Efficiency 84 %, 84.5 % | ||
Standards Met ANSI/AAMI ES60601-1 Standard, ANSI/AAMI File Number E314885-A11, CAN/CSA Medical C22.2 No. 60601-1:08 Standard, CAN/CSA Medical File Number E314889, CB Medical File Number E314885-A11, CB Medical IEC-60601-1 Standard, CE Certified, Conducted Immunity EN61 | ||
Minimum Temperature -40°C | ||
Related links
- Recom REM3 DC-DC Converter 5.5 → 9 V dc Input Through Hole, +105°C...
- Recom RS3 DC-DC Converter 18 → 36 V dc Input Through Hole, +71°C...
- Recom RSH3 DC-DC Converter 18 → 36 V dc Input Surface Mount, +81°C...
- Recom REM3 DC-DC Converter 9 → 18 V dc Input Through Hole, +105°C...
- Recom REC3 DC-DC Converter 18 → 36 V dc Input Through Hole, +85°C...
- Recom REM3 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C...
- Recom REM3 DC-DC Converter 18 → 36 V dc Input Through Hole, +105°C...
- Recom RI3 DC-DC Converter 24 V dc Input Through Hole, +85°C Max...