ABB GJL121 Contactor, 12V Coil, 3-Pole, 20 A, 4 kW 12V, 3 NO/1 NC, 250 V dc, 690V ac
- RS Stock No.:
- 253-4758
- Mfr. Part No.:
- GJL1213001R0017
- Manufacturer:
- ABB
This image is representative of the product range
Subtotal (1 pack of 10 units)*
MYR2,015.54
FREE delivery for orders over RM 500.00
Stocked by manufacturer
- Ready to ship from 26 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit | Per Pack* |
|---|---|---|
| 10 + | MYR201.554 | MYR2,015.54 |
*price indicative
- RS Stock No.:
- 253-4758
- Mfr. Part No.:
- GJL1213001R0017
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Coil Voltage | 12V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 250, 690V dc | |
| Contact Current | 20A | |
| Power Rating | 4kW | |
| Series | GJL121 | |
| Mount Type | DIN Rail, Wall | |
| Function | Mini Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Auxiliary Contact Configuration | 0 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Minimum Operating Temperature | -25°C | |
| Operational Current Ie | 20A | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 12V | |
| Maximum Operating Temperature | 55°C | |
| Length | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Depth | 46.7mm | |
| Width | 52.5mm | |
| Pole and Throw Configuration | 3P | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Coil Voltage 12V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 250, 690V dc | ||
Contact Current 20A | ||
Power Rating 4kW | ||
Series GJL121 | ||
Mount Type DIN Rail, Wall | ||
Function Mini Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Auxiliary Contact Configuration 0 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Minimum Operating Temperature -25°C | ||
Operational Current Ie 20A | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 12V | ||
Maximum Operating Temperature 55°C | ||
Length 46.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Depth 46.7mm | ||
Width 52.5mm | ||
Pole and Throw Configuration 3P | ||
ABB GJL121 Series Contactor, 20A Contact Current, 12V Coil Voltage - GJL1213001R0017
This contactor is a Compact switching device designed to control three-phase loads in commercial, industrial and residential electrical systems. It operates with a 12V control circuit and provides a mains switching solution for motors and power equipment up to 4kW, mounted on DIN rail or fixed to a wall for flexible installation in automated panels and distribution enclosures.
Features and Benefits:
• Three-pole switching delivers three independent line control and safety
• 20A operational current supports medium-duty motor and load switching
• 250V DC and 690V AC ratings allow use with DC and AC supply systems
• Single auxiliary contact offers control-circuit signalling and interlock
• Screw terminals enable secure terminations for repeated service
• Compliance with IEC/EN and UL standards assists regulatory acceptance
• 20A operational current supports medium-duty motor and load switching
• 250V DC and 690V AC ratings allow use with DC and AC supply systems
• Single auxiliary contact offers control-circuit signalling and interlock
• Screw terminals enable secure terminations for repeated service
• Compliance with IEC/EN and UL standards assists regulatory acceptance
Applications
• Suitable for contact control in industrial automation panels
• Ideal for motor switching in light commercial HVAC systems
• Used with residential distribution boards for load management
• Can be used for control of machinery in electronics assembly lines
• Ideal for motor switching in light commercial HVAC systems
• Used with residential distribution boards for load management
• Can be used for control of machinery in electronics assembly lines
What environmental temperatures will it tolerate in service?
It is specified to operate between -25°C and 55°C, allowing deployment in typical indoor and sheltered plantroom conditions.
What mounting arrangements are available for panel designers?
It supports both DIN rail attachment and direct wall mounting to suit differing panel layouts and enclosure types.
How many auxiliary contacts are provided for signalling?
There is one auxiliary contact arranged normally as 0NO/1NC to facilitate control logic and status feedback.
What are the physical connection details for electrical contractors?
Terminations use screw-type terminals to secure conductor connections during installation and maintenance.
Related links
- ABB GJL121 Contactor 3-Pole 3 NO/1 NC 690V ac
- ABB GJL121 Contactor 3-Pole 4 kW 12V 250 V dc, 690V ac
- ABB GJL121 Contactor 3-Pole 4 NO, 690V
- ABB GJL121 Contactor 3-Pole 4 kW 12V 690V
- ABB GJL121 Contactor 4-Pole 4 kW 12V 220V
- ABB GJL121 Contactor 3-Pole 3 NO 690V ac
- ABB GJL121 Contactor 240 V Coil 20 A 240 V 250 V dc, 690V ac
- ABB GJL121 Contactor 3-Pole 4 NO, 690V
