Better World
Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC, 1.8 → 2.6 A F.L.C, 2.6 A Contact Rating, 100 W,
- RS Stock No.:
- 758-951
- Mfr. Part No.:
- LR2K0308
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
MYR239.03
FREE delivery for orders over RM 500.00
In Stock
- 136 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | MYR239.03 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 758-951
- Mfr. Part No.:
- LR2K0308
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| FLC Motor Rating | 1.8 → 2.6 A | |
| Contact Current Rating | 2.6 A | |
| Range | TeSys | |
| Pole Configuration | 3P | |
| Series | TeSyS LR | |
| Mounting Style | Direct Contactor | |
| Power Rating | 100 W | |
| Normal State Configuration | NO/NC | |
| Reset Method | Automatic, Manual | |
| Terminal Type | Screw | |
| Width | 45mm | |
| Number Of Auxiliary Contacts | 2 | |
| Depth | 65mm | |
| Length | 116mm | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | +55°C | |
| Better World Verification | Green Premium | |
| Operating Temperature Range | -20 → +55 °C | |
| Better World Product | Yes | |
| Contact Voltage Rating | 690 V ac | |
| Control Voltage | 250 V dc, 690 V ac | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
FLC Motor Rating 1.8 → 2.6 A | ||
Contact Current Rating 2.6 A | ||
Range TeSys | ||
Pole Configuration 3P | ||
Series TeSyS LR | ||
Mounting Style Direct Contactor | ||
Power Rating 100 W | ||
Normal State Configuration NO/NC | ||
Reset Method Automatic, Manual | ||
Terminal Type Screw | ||
Width 45mm | ||
Number Of Auxiliary Contacts 2 | ||
Depth 65mm | ||
Length 116mm | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +55°C | ||
Better World Verification Green Premium | ||
Operating Temperature Range -20 → +55 °C | ||
Better World Product Yes | ||
Contact Voltage Rating 690 V ac | ||
Control Voltage 250 V dc, 690 V ac | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CZ
Schneider Electric LR2K Series Thermal Overload Relay, 1.8 to 2.6 A FLC Motor Rating, 100W - LR2K0308
This thermal overload relay is essential for ensuring efficient motor protection. Designed for use in various industrial applications, it has a compact profile of 45mm width, 65mm depth, and 116mm length. The product accommodates a current rating of 1.8 to 2.6A and operates effectively within a temperature range of -20°C to +55°C, making it a robust choice for diverse environments.
Features & Benefits
• Provides automatic and manual reset options for convenience
• Designed with 1 NO + 1 NC configuration for versatile applications
• Utilises screw clamp terminals for reliable connections
• Supports a high contact current rating of 2.6A for enhanced performance
• Offers compatibility with multiple motor types for flexible usage
• Designed with 1 NO + 1 NC configuration for versatile applications
• Utilises screw clamp terminals for reliable connections
• Supports a high contact current rating of 2.6A for enhanced performance
• Offers compatibility with multiple motor types for flexible usage
Applications
• Used for motor protection against overload conditions
• Suitable for applications involving both AC and DC networks
• Ideal for integration with LP4K, LC1K, and LC7K components
• Employed where temperature stability is critical
• Suitable for applications involving both AC and DC networks
• Ideal for integration with LP4K, LC1K, and LC7K components
• Employed where temperature stability is critical
Is it suitable for signalling circuits?
Yes, it supports various signalling circuit voltages.
Will it provide phase failure sensitivity?
Yes, phase failure sensitivity is included for added safety.
Can it connect multiple cable types?
Yes, it accommodates multiple solid and flexible cables.
Does it meet environmental standards?
Yes, it complies with several international safety standards.
Related links
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 3.7 A Contact Rating
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 1.8 A Contact Rating
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 5.5 A Contact Rating
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 11.5 A Contact Rating
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 10 A Contact Rating
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 1.2 A Contact Rating
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 8 A Contact Rating 250 V
- Schneider Electric TeSyS LR Thermal Overload Relay 1NO + 1NC 690 V ac, TeSys Deca