An oscilloscope is considered to be the most used instrument for electrical engineers who need to measure electrical characteristics of electronic devices but you also need at least one probe.
Things to consider when choosing probes
• Ensure the probe's input connector matches the connector on your scope
• Choose a probe whose input resistance and capacitance match the input resistance and capacitance of your scope - matching is critical for guaranteeing proper signal transfer and signal accuracy
The best approach, for matching a probe with a scope, is to first choose a probe whose capacitance is within the range of your scope and then fine-tune the probe's capacitance by adjusting its compensation network using the probe's trimmer capacitor.
The 1X probes are suitable for many low frequency applications. They typically offer the same input impedance of the oscilloscope which is normally 1 M Ohm. The most common type of probe with a built in attenuator gives an attenuation of ten, and it is known as a 10X oscilloscope probe
Types of probes
Passive probes are the most commonly used probes for taking measurements. They are easy to use, relatively inexpensive, and fairly rugged. Available in the following configurations:
• 1´: no attenuation
• 10´: factor-of-10 attenuation
• 100´: factor-of-100 attenuation
• 1000´: factor-of-1000 attenuation
Attenuation probes serve to multiply the voltage measurement range of the oscilloscope by using an internal resistor that, when used in conjunction with the input resistance of the scope, creates a voltage divider. Useful for the following reasons:
• It allows for the measurement of a signal that might exceed the limits of the oscilloscope.
• The attenuation circuitry results in higher resistance and lower capacitance, which is important for high-frequency measurements.
Active probes contain active components, such as FETs or amplifiers. Commonly used for taking high-speed measurements (>500 MHz) or on high-impedance circuits. One limitation is their limited voltage range.
Differential probes are popular for measuring high-frequency signals or signals of very low amplitude.
A current probe measures the electrical current flowing through a conductor.
Tips
• Always use an appropriate probe tip and/or probe tip adapter whenever possible
• Keep ground leads short

...
Read more Read less

Filters

Viewing 41 - 60 of 188 products
Results per page
Description Price Probe Type Attenuation Bandwidth Maximum Common Mode Input Voltage Connector Type Model Number p Number of Probes Safety Category Level Safety Category Voltage Series Safety Category Rise Time
RS Stock No. 734-5029
Mfr. Part No.P5200A
BrandTektronix
MYR6,014.74
Each
units
Differential, High Voltage 1:50, 1:500 50MHz 1kV - P5200A - CAT II 1000V P52XXA CAT II 1000 V -
RS Stock No. 512-6078
Mfr. Part No.TT-SI 9010
BrandTestec
MYR4,632.19
Each
units
Active, Differential 1:100, 1:1000 70MHz 5kV BNC TT-SI 9010 - CAT I, CAT II 2500 V ac, 7000 V ac/dc SI CAT I 2500 V ac, CAT II 7000 V ac/dc 5ns
RS Stock No. 733-6148
Mfr. Part No.N2796A
MYR11,130.84
Each
units
Active 1:10 2GHz - - N2796A - - - N - 175ps
RS Stock No. 733-6145
Mfr. Part No.N2791A
MYR3,250.17
Each
units
Differential 1:10, 1:100 25MHz 700V BNC N2791A - CAT II 1000V ac N CAT II 1000 V ac 14ns
RS Stock No. 781-0810
Mfr. Part No.TCP305A
BrandTektronix
MYR10,084.57
Each
units
Current - 50MHz - BNC TCP305A 1 CAT II 150 V, 300 V TCP300 CAT II 150 V, CAT II 300 V 7ns
RS Stock No. 678-4016
Mfr. Part No.PMT201A
BrandPMK
MYR342.69
Each
units
Passive 1:1 55MHz - BNC PMT201A - CAT II 55V PMT CAT II 55V 12ns
RS Stock No. 898-6826
Mfr. Part No.TA150
MYR809.85
Each
units
Passive 1:10 350MHz - BNC - 1 CAT II - - - 1ns
RS Stock No. 898-6750
Mfr. Part No.TA044
MYR4,181.68
Each
units
Active, Differential 1:100, 1:1000 70MHz 5kV - - 2 CAT I 2500 Vrms, 7000 V ac/dc - 2500 Vrms, CAT I 7000 V ac/dc 5ns
RS Stock No. 714-0035
Mfr. Part No.10074D
MYR1,012.46
Each
units
Passive 1:10 150MHz - BNC 10074D - CAT I, CAT II 400 V, 500 V - CAT I 500 V, CAT II 400 V 2.33ns
RS Stock No. 796-6702
Mfr. Part No.P6015A
BrandTektronix
MYR10,892.40
Each
units
High Voltage 1:1000 75MHz 20kV - P6015A 1 - - - - 4ns
RS Stock No. 678-4000
Mfr. Part No.PMS211A
BrandPMK
MYR272.19
Each
units
Passive 1:10 150MHz - BNC PMS211A - CAT II 300V PMS CAT II 300 V 2.4ns
RS Stock No. 898-6766
Mfr. Part No.TA057
MYR1,828.55
Each
units
Active, Differential 1:20, 1:200 25MHz 1kV - - 2 CAT III 1000 Vrms, ±1400 V - 1000 Vrms, CAT III ±1400 V -
RS Stock No. 781-0813
Mfr. Part No.P6021A
BrandTektronix
MYR10,128.11
Each
units
Current - 60MHz - BNC P6021A 1 - - - - -
RS Stock No. 702-3902
Mfr. Part No.N2873A
MYR2,207.99
Each
units
Passive 1:10 500MHz - BNC N2873A - CAT I, CAT II 300 V, 400 V N2870A CAT I 400 V, CAT II 300 V -
RS Stock No. 801-4868
Mfr. Part No.AP031
BrandLeCroy
MYR3,022.31
Each
units
Differential 1:10, 1:100 25MHz 700V BNC AP031 - CAT III 1000V - CAT III 1000 V 14ns
RS Stock No. 575-585
Mfr. Part No.P2221
BrandTektronix
MYR713.15
Each
units
Passive 1:1, 1:10 200MHz - - P2221 - CAT II 150 V, 300 V - CAT II 15 V, CAT II 300 V -
RS Stock No. 512-6438
Mfr. Part No.TT-SI 9101
BrandTestec
MYR4,167.10
Each
units
Active, Differential 1:10, 1:100 100MHz 1kV BNC TT-SI 9101 - CAT III 1000V ac SI CAT III 1000 V ac 3.5ns
RS Stock No. 366-9141
Mfr. Part No.TT-HVP15 HF
BrandTestec
MYR1,047.41
Each
units
Passive 1:1000 50MHz 10kV BNC TT-HVP15 HF - CAT I - HVP - 7ns
RS Stock No. 898-6741
Mfr. Part No.TA043
MYR3,003.74
Each
units
Active, Differential 1:10, 1:100 100MHz 700V - - 2 CAT III 500 Vrms, 700 V ac/dc - 500 Vrms, CAT III 700 V ac/dc 3.5ns
RS Stock No. 898-6747
Mfr. Part No.TA042
MYR2,741.95
Each
units
Active, Differential 1:100, 1:1000 100MHz 1kV - - 2 CAT III 1000 Vrms, 1400 V ac/dc - 1000 Vrms, CAT III 1400 V ac/dc 3.5ns
Related Products
MDO3000 oscilloscopes are designed to meet users' needs ...
Description:
MDO3000 oscilloscopes are designed to meet users' needs and aspirations now and into the future. Each model is multi-functional with integrated basic spectrum analyzer, Wave Inspector Navigation, MSO, serial and parallel bus triggering and analysis, and digital voltmeter. Optional instrument ...
Bandwidth 500 MHzProbe Ratio 10:1Cable Length 1.2 metersInput ...
Description:
Bandwidth 500 MHzProbe Ratio 10:1Cable Length 1.2 metersInput Impedance 10 MOhmCapacitance 12 pFApprox. Rise Time 3 nsMax. Voltage 1000 V CAT III / 600 V CAT IVCompensation Range 10 to 22 pFSafety Rating 1000 V CAT III / 600 V ...
Compact design with a 2.5mm probe tip diameter ...
Description:
Compact design with a 2.5mm probe tip diameter provides better visibility to the circuit under test than conventional 5mm or 3.5mm probe tips. This makes it easier to probe today’s fine pitched space ICs and components. The replaceable probe tip ...
LeCroy passive probes automatically scale the oscilloscope waveforms ...
Description:
LeCroy passive probes automatically scale the oscilloscope waveforms without user input. They are optimised for maximum waveform fidelity, including high frequency signal components, in a rugged design suitable for everyday use.