PR Electronics Programmable Signal Conditioner, Signal Calculator, Current, RTD, Thermocouple, Voltage Input, Current,
- RS Stock No.:
- 827-5489
- Mfr. Part No.:
- 5115A
- Manufacturer:
- PR Electronics
2 In Global stock for delivery in 4-6 working days, delivery time may vary for certain locations or FTZ
Added
Price Each
MYR4,614.85
Units | Per Unit |
1 + | MYR4,614.85 |
- RS Stock No.:
- 827-5489
- Mfr. Part No.:
- 5115A
- Manufacturer:
- PR Electronics
Legislation and Compliance
- COO (Country of Origin):
- DK
Product Details
PR Electronics 5115A Signal Calculator
PR Electronics 5115A programmable transmitter for redundancy measurement of temperature by means of two sensors, where the secondary sensor takes over the measurement when a sensor error occurs on the primary sensor. With a wide variety of jumper selectable inputs for current/voltage or temperature and conversion of linear resistance the 5114 transmitters are suitable for a wide range of temperature measurement applications.
The 5115A transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit (RS stock number 796-7020).
The 5115A signal conditioner is based on a microprocessor core with an efficient program operation. The basic calibration data and present set-up are stored in an EEPROM thereby avoiding the loss or change of data at power off.
The 5115A transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit (RS stock number 796-7020).
The 5115A signal conditioner is based on a microprocessor core with an efficient program operation. The basic calibration data and present set-up are stored in an EEPROM thereby avoiding the loss or change of data at power off.
Features and Benefits
Redundancy measurement with 2 input signals
Input for RTD, TC, mV, linear resistance, mA and V
Signal calculator with four arithmetical operations: Addition, subtraction, multiplication and division
LED indicators for normal operation, sensor error on each sensor, and functional error
Universal voltage supply
3.75 kVac galvanic isolation
Duplication of the input signal to two separate analogue outputs
Input for RTD, TC, mV, linear resistance, mA and V
Signal calculator with four arithmetical operations: Addition, subtraction, multiplication and division
LED indicators for normal operation, sensor error on each sensor, and functional error
Universal voltage supply
3.75 kVac galvanic isolation
Duplication of the input signal to two separate analogue outputs
PR Electronics DIN Rail Mounting
Specifications
Attribute | Value |
---|---|
Module Type | Signal Calculator |
Barrier Type | Galvanic Barrier |
Output Signal Type | Current, Voltage |
Input Signal Type | Current, RTD, Thermocouple, Voltage |
Supply Voltage | 19.2 → 300 V dc, 21.6 → 253V ac |
Minimum Operating Temperature | -20°C |
Maximum Operating Temperature | +60°C |
Safety Current Maximum | 400mA |
Safety Voltage Maximum | 250 V ac |
Series | 5115A |
Operating Temperature Range | -20 → +60°C |