Honeywell Commercial Thermostat Thermostat, 150 °C Max Open On Rise, Manual Reset, SPST, 10 A, Bracket
- RS Stock No.:
- 228-2591
- Distrelec Article No.:
- 303-99-482
- Mfr. Part No.:
- 2455RM-90820471
- Manufacturer:
- Honeywell
Bulk discount available
Subtotal (1 unit)*
MYR232.80
FREE delivery for orders over RM 500.00
In Stock
- 1,377 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 - 14 | MYR232.80 |
| 15 - 74 | MYR227.91 |
| 75 + | MYR187.58 |
*price indicative
- RS Stock No.:
- 228-2591
- Distrelec Article No.:
- 303-99-482
- Mfr. Part No.:
- 2455RM-90820471
- Manufacturer:
- Honeywell
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Minimum Operating Temperature | 0°C | |
| Product Type | Thermostat | |
| Maximum Operating Temperature | 150°C | |
| Thermostat Type | Commercial Thermostat | |
| Contact Configuration | SPST | |
| Contact AC Voltage | 250V ac | |
| Terminal Type | Solder Tab | |
| Contact Current | 10A | |
| Hazardous Area Certification | NO | |
| Standards/Approvals | RoHS | |
| Series | 2455RM | |
| Reset Type | Manual | |
| Mount Type | Bracket | |
| Switch Function | Open On Rise | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Minimum Operating Temperature 0°C | ||
Product Type Thermostat | ||
Maximum Operating Temperature 150°C | ||
Thermostat Type Commercial Thermostat | ||
Contact Configuration SPST | ||
Contact AC Voltage 250V ac | ||
Terminal Type Solder Tab | ||
Contact Current 10A | ||
Hazardous Area Certification NO | ||
Standards/Approvals RoHS | ||
Series 2455RM | ||
Reset Type Manual | ||
Mount Type Bracket | ||
Switch Function Open On Rise | ||
- COO (Country of Origin):
- CN
Honeywell 2455RM Series Thermostat, 250V AC Contact Voltage, 10A Contact Current - 2455RM-90820471
This thermostat is a commercial temperature cut-off switch designed to interrupt circuits when temperatures rise. It operates as a single-pole single-throw device for control tasks in industrial and HVAC environments, mounted via a bracket and intended for manual reset after actuation. The unit is suitable for systems requiring a straightforward open-on-rise safety function and solder-tab electrical connections.
Features and Benefits:
• Opens circuit on temperature rise for overheat protection
• Manual reset function enables controlled system restart
• Rated for 250VAC operation to handle mains voltages
• 10A contact capacity supports common load currents
• Solder-tab terminals allow secure PCB or wiring attachment
• Withstands up to 150°C for high-temperature applications
• Manual reset function enables controlled system restart
• Rated for 250VAC operation to handle mains voltages
• 10A contact capacity supports common load currents
• Solder-tab terminals allow secure PCB or wiring attachment
• Withstands up to 150°C for high-temperature applications
Applications
• Suitable for commercial HVAC limit to prevent overheating
• Used for thermal protection in industrial control panels
• Ideal for electrical heating assemblies requiring manual reset
• Can be used for automation equipment temperature cut-off tasks
• Used for thermal protection in industrial control panels
• Ideal for electrical heating assemblies requiring manual reset
• Can be used for automation equipment temperature cut-off tasks
What contact arrangement does it use and how does that affect wiring?
It uses a single-pole single-throw contact, providing a simple series break suitable for inserting into control or safety loops where a single switching element is required.
How should the device be mounted in equipment?
The bracket mount permits fixed attachment to frames or panels
secure mechanical mounting ensures reliable temperature sensing and prevents movement that could affect trips.
What reset action is required after an actuation?
Following activation, a manual intervention resets the mechanism, allowing inspection and deliberate restart rather than automatic reclosure.
Which environments are unsuitable based on temperature limits?
It should not be used in locations that routinely fall below 0°C or exceed 150°C, as those conditions lie outside the specified operating range.
What approvals or material restrictions are noted?
The component complies with RoHS requirements, indicating restriction of certain hazardous substances in its construction.
Approvals
UL recognised component, CSA Certified
Related links
- Honeywell Bi-Metallic Thermostat Manual Reset 10 A, Bracket Mount
- Honeywell Bi-Metallic Thermostat 150 °C Max NC 10 A, Bracket Mount
- Honeywell Bi-Metallic Thermostat 150 °C Max NC SPST Bracket
- Honeywell Bi-Metallic Thermostat 150 °C Max NC SPST Bracket
- Honeywell Bi-Metallic Thermostat 260 °C Max NO SPST-NC Bracket
- Honeywell Bi-Metallic Thermostat 186 °C Max SPST Bracket
- Honeywell Bi-Metallic Thermostat 186 °C Max SPST Bracket, Terminal
- Honeywell Bi-Metallic Thermostat 260 °C Max NO SPST-NC Bracket Mount