OD Series Signal Conditioning Modules

The OD series conditioning unit is used to interface with Solartron Metrologys range of sensors and will provide a different functionality to suit different applications. The DRC version is a DIN rail mounted signal conditioning unit and is powered from a single 10 → 30 Vdc supply. The outputs of this module are fully adjustable allowing a range of voltage and current outputs to be selected.

Specifications
Attribute Value
Input Type Voltage
Output Type Current
Signal Conditioner Type Voltage to Current
Input Range 55 → 5000 mV
Output Range ±10 V dc, ±20 mA
Supply Voltage 10 → 30 V dc
Mounting Type DIN Rail
Minimum Operating Temperature 0°C
Maximum Operating Temperature +60°C
Operating Temperature Range 0 → +60 °C
5 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 1,828.98
units
Per unit
1 +
MYR1,828.98
Related Products
The intrinsically safe interface blocks of the MACX ...
Description:
The intrinsically safe interface blocks of the MACX Analog Ex series offer the widest range of functions in the narrowest design. Ex-i signal conditioner for many applicationsElectrical 3-way isolationScrew or spring-cage connections are availableIP20 protectionWidth only 12.5 mm.
MurrElektronik MTW 12.4 series temperature monitoring relays are ...
Description:
MurrElektronik MTW 12.4 series temperature monitoring relays are designed specially for monitoring abnormal temperatures to prevent excessive temperature increase and to protect equipment. The temperature converter works in conjunction with a PT100 temperature sensor and convert the temperature into a ...
Monitoring or control of temperature - 50°C to ...
Description:
Monitoring or control of temperature - 50°C to +300°C in 5 rangesCompensated 3-wire PT100 sensor operationAdjustable setpointHysteresis adjustable ±0.5 to 20% of selected rangeInversion of the relay contact function - heating/cooling control0-10V analogue outputs for both Setpoint and Measured valueLED ...
Millenium 2 Plus has been designed to automate ...
Description:
Millenium 2 Plus has been designed to automate building and smaller machine applications. Many pre-programmed standard functions are available for counting, timing, comparison, multiplexing, time based programming, etc.,Non-expandable, expandable, and application specific starter kits are also available. All ...