Chauvin Arnoux PO1120074A Multimeter Current Clamp Adapter, 450mA dc, 300mA ac, 3.9mm

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): US
Product Details

K1 and K2 low-current probes

Current probes to measure low DC and AC currents.
Easily adapted to all 19 mm standard spacing multimeters.
Zero reset using a thumb wheel with disable feature.
2 LEDs display overload (red LED) and the correct battery level (green LED).
Applications: loop measurements 4 → 20 mA without opening the circuit, low current measurements, default current measurements etc.


Standard: IEC 1010-1, 600 V Cat. III, deg. 2 if used with a multimeter of the same category.

Specifications
Attribute Value
Adapter Type AC/DC
Maximum DC Current 450mA
Maximum AC Current 300mA ac
Best Accuracy ±1 %
Resolution 50 (DC) μA, 100 (AC) μA
Maximum Conductor Size 3.9mm
Safety Category CAT II 300 V
Output Type Current
Connector Type 4 mm Plug
Battery Type 9V
Battery Life 20 h
Cable Length Extended 1.5m
Maximum Operating Temperature +55°C
Minimum Operating Temperature -10°C
Model Number p PO1120074A
Safety Category Voltage 300V
Safety Category Level CAT II
2 Within 4 working day(s) (Global stock)
4 Within 4 working day(s) (Global stock)
Price Each
MYR 3,078.97
units
Per unit
1 +
MYR3,078.97
Related Products
Standard AC current pliers Inspired by the principle ...
Description:
Standard AC current pliers Inspired by the principle of the Rogowski coil.Can measure intensity up to 3000 A when used with oscilloscopes and recorders.Its flexible measurement head is light and can be easily and quickly installed into hard-to-reach places.Three ranges: ...
ICA39T from the RS Pro range of current ...
Description:
ICA39T from the RS Pro range of current clamp adapters. 1.9% basic D CA / A CA accuracyNon-intrusive transducingUp to 29 mm Diameter conductorShock Proof: 5 ft dropCoiled cable output plugsErgonomically designed jaw and triggerAC-DC 1000 A capabilityAuto-zero key for ...
RS Pro ICA 15 AC Current adapter is ...
Description:
RS Pro ICA 15 AC Current adapter is designed to plug into the IDM 17 probe style multimeter. AC 300 A capability1.9% basic ACA accuracyNon-intrusive transducingUp to 29 mm dia. conductorErgonomically designed jaw and triggerHand guard designedCAT.II 600 V Safety ...
Rugged current clamp adaptor suitable for use with ...
Description:
Rugged current clamp adaptor suitable for use with multimeters to give non intrusive measurement of d.c. and a.c. current. Integral 1.2m 4mm shrouded plug lead. Jaws accept conductor size of 1 x 30mm or 2 x 25mm dia.d.c. current zero ...