Various Thermocouple Input Temperature Transmitter, 10 → 30 V dc, 0 → +70 °C

  • RS Stock No. 363-0222
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

TX104TC In-Head Thermocouple

The transmitter has user selection of thermocouple type
Re-rangeable via solder links and potentiometers
Operating Temperature Range: 0°C to +70°C
Dimensions: H23mm x Dia 42mm

Note

Initial temperature range refers to the factory - set temperature range for each product. The range may be re-configured to suit the individual requirements specified by the user.

Temperature Transmitters

4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software

Specifications
Attribute Value
Input Type Thermocouple Type J, Thermocouple Type K, Thermocouple Type T
Supply Voltage 10 → 30 V dc
Diameter 42 mm
Minimum Operating Temperature 0°C
Maximum Operating Temperature +70°C
Series RS PRO
Depth 23mm
30 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 432.31
units
Per unit
1 +
MYR432.31
Related Products
2-wire programmable transmitter can be programmed to measure ...
Description:
2-wire programmable transmitter can be programmed to measure temperatures within all RTD ranges defined by the standards and has a high measurement accuracy. RTD or Ohm inputThree wire connectionCan be installed in Ex zone 01 (136-8673) or 2 (136-8674) channel ...
2-wire programmable transmitter can be programmed to measure ...
Description:
2-wire programmable transmitter can be programmed to measure temperatures within all TC ranges defined by the standards and has a high measurement accuracy. TC InputGalvanic IsolationProgrammable sensor error value1 (136-8677) or 2 (136-8676) channel options availableDIN Rail mounting (vertically or ...
The 6350B is a bus transmitter with both ...
Description:
The 6350B is a bus transmitter with both PROFIBUS PA and FOUNDATION Fieldbus communication. A unique switch function ensures automatic shift between the two protocols. 1 (136-8685) or 2 (136-8686) channel versions availablePROFIBUS PA version 3.0FOUNDATION Fieldbus version ITK 4.6FISCO ...
RTD, TC, potentiometer, linear resistance and bipolar mV ...
Description:
RTD, TC, potentiometer, linear resistance and bipolar mV inputSingle or true dual inputs with sensor redundancy and drift detectionHigh accuracy across a wide ambient operating temperature of -50 to +85°C2.5 kVAC galvanic isolationApplication:Temperature measurement of a wide range of TC ...