Roxburgh EMC 320 V ac, 420 V ac 20kA DVSB Lightning Protector, DIN Rail Mounting

  • RS Stock No. 707-9804
  • Mfr. Part No. DVSB400654TNS
  • Manufacturer Roxburgh EMC
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

MOV Module, Roxborough EMC DVSB

Dual high-energy electrically isolated metal oxide varistors
Single and 3 phase line protection from surges and lightning
Modular design to snap-fit directly onto top hat profile DIN rails
Remote operation contacts for protection indication

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Specifications
Attribute Value
Suppressor Type Lightning Protector
Maximum Voltage Rating 320 V ac, 420 V ac
Mounting Type DIN Rail
Maximum Surge Current 20kA
Series DVSB
Length 72mm
Depth 70mm
Height 90mm
Dimensions 72 x 70 x 90mm
Minimum Operating Temperature -40°C
Maximum Operating Temperature +80°C
13 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 1,686.93
units
Per unit
1 - 4
MYR1,686.93
5 - 9
MYR1,616.66
10 - 24
MYR1,566.13
25 - 49
MYR1,531.07
50 +
MYR1,498.24
Related Products
Frequency error range detection 35-75 HzOperating voltage 90V ...
Description:
Frequency error range detection 35-75 HzOperating voltage 90V to 300VLow voltage protection (LVD) Range 50V to 300VHigh voltage protection (HVD) Range 50V to 300V TimeSave™ function (Intelligent time delay)AVS™ function (Automatic Voltage Switcher) Programmable startup delay (0-1000hr range).
STP T23 20 is the series of combined ...
Description:
STP T23 20 is the series of combined Type 2+3/Class II+III devices for discharging voltage surges while providing a very fine voltage protection level. Suitable as the final stage of protection in panels with Type 2 protection devices installed upstream ...
STM T23 20 S is the series of ...
Description:
STM T23 20 S is the series of combined Type 2+3/Class II+III devices for discharging voltage surges while providing a very fine voltage protection level. Suitable as the final stage of protection in panels with Type 2 protection devices installed ...
Contact suppressors comprising a resistor and capacitor in ...
Description:
Contact suppressors comprising a resistor and capacitor in series improve contact lifeMay be connected across a switch or relay contacts to suppress interference generated when switching reactive loadsSelf healing construction and self extinguishing case.