Cooper Bussmann 10A A1 T British Standard Fuse, gG, gM, 550V ac

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): IN
Product Details

Red Spot™ Range, Type ’T’ HBC

As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A

Breaking capacity 80kA ac 40kAdc
Rated up to 550Vac/ 250Vdc (Type A1) & 660Vac/ 460Vdc (Type A2)
General purpose (gG) and dual motor rated (gM) types
Low power dissipation
660Vac rated (A1 types 415Vac)
ASTA 20 certified

Specifications
Attribute Value
Fuse Standard BS 88-2:1988, IEC 60269-2
Fuse Size A1
Current Rating 10 A
Voltage Rating 550 V ac
Fuse Speed T
High Rupture Capacity Yes
Body Diameter 14.1mm
Overall Length 55.6mm
Tag Width 11.1mm
Body Height 36.5mm
Fixing Centres 44.5mm
Application Category GG, GM
660 In Global stock for delivery within 4 - 6 working days
Price Each (In a Pack of 5)
MYR 15.448
units
Per unit
Per Pack*
5 - 20
MYR15.448
MYR77.24
25 - 120
MYR13.06
MYR65.30
125 - 245
MYR11.214
MYR56.07
250 - 495
MYR10.036
MYR50.18
500 +
MYR9.43
MYR47.15
*price indicative
Related Products
Rated up to 550Vac (SSD types 240Vac/120Vdc)Low power ...
Description:
Rated up to 550Vac (SSD types 240Vac/120Vdc)Low power loss, typically 20% lower than the requirements of BS88Suitable for type 2 co-ordinated applications as defined in IEC 947-4Suitable for three-phase applicationsGeneral purpose (gG) and dual motor rated (gM) typesTime/current characteristics (IEC ...
Rated up to 550Vac (SSD types 240Vac/120Vdc)Low power ...
Description:
Rated up to 550Vac (SSD types 240Vac/120Vdc)Low power loss, typically 20% lower than the requirements of BS88Suitable for type 2 co-ordinated applications as defined in IEC 947-4Suitable for three-phase applicationsGeneral purpose (gG) and dual motor rated (gM) typesTime/current characteristics (IEC ...
These fuses are designed for : “General purpose ...
Description:
These fuses are designed for : “General purpose use” protection (gG type) or motor protection (gM type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by ...
Breaking capacity 80kA at 415Vac and 40kA at ...
Description:
Breaking capacity 80kA at 415Vac and 40kA at 250Vdc (bolted connection types) (E1 type 16·5kA at 240Vac)Rated at 415Vac/250Vdc (bolted connection types) (E1 type 240Vac)Electricity Supply Authorities, Lloyd’s Register of Shipping Approvals and ASTA 20 certified.