TE Connectivity RTD RTD Sensor 9.65 mm Long, 2 Wire, 125 °C max
- RS Stock No.:
- 613-514
- Mfr. Part No.:
- 20016752-01
- Manufacturer:
- TE Connectivity
Subtotal (1 unit)*
MYR4,321.69
FREE delivery for orders over RM 150.00
Temporarily out of stock
- Shipping from 11 January 2027
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per Unit |
|---|---|
| 1 + | MYR4,321.69 |
*price indicative
- RS Stock No.:
- 613-514
- Mfr. Part No.:
- 20016752-01
- Manufacturer:
- TE Connectivity
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | TE Connectivity | |
| Sensor Type | RTD | |
| Product Type | RTD Sensor | |
| Probe Length | 9.65mm | |
| Minimum Temperature Sensed | 60°C | |
| Maximum Temperature Sensed | 125°C | |
| Termination Type | Crimp | |
| Series | 20016752-01 | |
| Cable Length | 1m | |
| Probe Material | Platinum | |
| Number of Wires | 2 | |
| Hazardous Area Certification | No | |
| Select all | ||
|---|---|---|
Brand TE Connectivity | ||
Sensor Type RTD | ||
Product Type RTD Sensor | ||
Probe Length 9.65mm | ||
Minimum Temperature Sensed 60°C | ||
Maximum Temperature Sensed 125°C | ||
Termination Type Crimp | ||
Series 20016752-01 | ||
Cable Length 1m | ||
Probe Material Platinum | ||
Number of Wires 2 | ||
Hazardous Area Certification No | ||
- COO (Country of Origin):
- IE
The TE Connectivity RTD Platinum Sensor is connected to 26 AWG polyimide insulated twisted pair lead wires for accurate signal transmission. It is encapsulated in epoxy resin and mounted on a flat aluminum alloy housing for thermal efficiency and mechanical protection. The sensor-to-lead connection is made using an ESCC qualified welding/crimping interconnection method, ensuring high reliability and durability in critical applications.
Flat Aluminum housing for surface mounting
26 AWG polyimide insulated twisted pair lead wire
Lead length available in 4x different options
Electrical resistance calibrated at other temperatures per customer request