Jumo di eco On/Off Temperature Controller, 76 x 36 mmmm, Current Input, 230 V ac Supply

  • RS Stock No. 613-7798
  • Mfr. Part No. 701540/831-02
  • Manufacturer Jumo
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

di eco temperature indicator

PT100 and PT1000 probe temperature indicator, J, K and L thermocouples and 4 // 20 mA, 0 // 20 mA analogue output.
3-digit indicator with red backlighting.
1 C/O relay output in case of setpoint being exceeded.
Supply voltage: 230 Vac

Specifications
Attribute Value
Input Type Current
Output Type 1 Relay
Number of Outputs 1
Supply Voltage 230 V ac
Size 76 x 36 mmmm
Minimum Operating Temperature 0°C
Maximum Operating Temperature +55°C
IP Rating IP20, IP65
Mounting Type Panel Mount
Series di eco
3 Within 4 working day(s) (Global stock)
11 Within 4 working day(s) (Global stock)
Price Each
MYR 481.44
units
Per unit
1 +
MYR481.44
Related Products
Automatic maximum & minimum storageDecimal point selectableReverse polarity ...
Description:
Automatic maximum & minimum storageDecimal point selectableReverse polarity protection5 measurements per second (display refresh every 1-2 seconds)Resolution: 0.01°C (0.1°F) or 1°C (1°F)Accuracy: PT100 0.1%, Ni100 0.2%Temperature drift: 0.01K/K ambientOperating temperature: -20 to +65°CDIN 24 x 48mm housing; ...
PT100 InputHeating or cooling is configurableLimit monitoringAdjustable switching ...
Description:
PT100 InputHeating or cooling is configurableLimit monitoringAdjustable switching hysteresisSimple, Space saving installationTime delayed switch-on after power-on selectable3 digit LCD with special characters for °F and °CParameter level protected by code.
PT100 InputIntegrated defrosting functionHeating or cooling is configurableLimit ...
Description:
PT100 InputIntegrated defrosting functionHeating or cooling is configurableLimit monitoringAdjustable switching hysteresisTime delayed switch-on after power-on selectableOperating hours counterSymbols for operating modes, °C, °F, hours, minutes and seconds on displayParameter level protected by codeSetup program ...
PT100 InputIntegrated defrosting functionHeating or cooling is configurableLimit ...
Description:
PT100 InputIntegrated defrosting functionHeating or cooling is configurableLimit monitoringAdjustable switching hysteresisTime delayed switch-on after power-on selectableOperating hours counterSymbols for operating modes, °C, °F, hours, minutes and seconds on displayParameter level protected by codeSetup program ...