Fluke 376 Clamp Meter, 999.9A dc, Max Current 2.5kA ac CAT III 1000 V, CAT IV 600 V
- RS Stock No.:
- 705-1932
- Mfr. Part No.:
- FLUKE-376/E
- Manufacturer:
- Fluke
Discontinued product
Alternatives
This product is not currently available. Here are our alternative recommendations.
Each
MYR1,743.00
Each
MYR1,499.12
- RS Stock No.:
- 705-1932
- Mfr. Part No.:
- FLUKE-376/E
- Manufacturer:
- Fluke
- COO (Country of Origin):
- CN
Fluke 376 True RMS AC/DC Clampmeter with iFlex
The Fluke 376 clampmeter offers improved performance for a wide range of current measurement situations. With True RMS voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. The new 18 in (458 mm) iFlex flexible current probe is included. It expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward-sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 clampmeter.
Features & Benefits
Large backlit display
1000 A ac and dc current measurement with fixed jaws
2500 A ac current measurement with iFlex flexible current probe
1000 V ac (True RMS) and dc voltage measurement
500 mV dc measurement range to interface with other accessories
Frequency, capacitance, resistance and continuity measurement
Display HOLD, Min, max, average and inrush recording
Low pass filter for stable readings in noisy environments
CAT IV 600 V, CAT III 1000 V safety rating
1000 A ac and dc current measurement with fixed jaws
2500 A ac current measurement with iFlex flexible current probe
1000 V ac (True RMS) and dc voltage measurement
500 mV dc measurement range to interface with other accessories
Frequency, capacitance, resistance and continuity measurement
Display HOLD, Min, max, average and inrush recording
Low pass filter for stable readings in noisy environments
CAT IV 600 V, CAT III 1000 V safety rating
Measurement Range Resolution Accuracy
Measurement Range Resolution Accuracy
AC Current via Jaw 1000 A 0.1 A ±(2% + 5 d)
AC Current via iFlex 2500 A 0.1 A ±(3% + 5 d)
DC Current 1000 A 0.1 A ±(2% + 5 d)
AC Voltage 1000 V 0.1 V ±(1.5% + 5 d)
DC Voltage 1000 V 0.1 mV ±(1% + 5 d)
Resistance 60000 Ω 0.1 Ω ±(1% + 5 d)
Frequency 500 Hz 0.1 Hz ±(0.5% + 5 d)
Capacitance 1000 μF 1 μF ±(1% + 4 d)
Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)
AC Current via Jaw 1000 A 0.1 A ±(2% + 5 d)
AC Current via iFlex 2500 A 0.1 A ±(3% + 5 d)
DC Current 1000 A 0.1 A ±(2% + 5 d)
AC Voltage 1000 V 0.1 V ±(1.5% + 5 d)
DC Voltage 1000 V 0.1 mV ±(1% + 5 d)
Resistance 60000 Ω 0.1 Ω ±(1% + 5 d)
Frequency 500 Hz 0.1 Hz ±(0.5% + 5 d)
Capacitance 1000 μF 1 μF ±(1% + 4 d)
Fixed jaw capacity 32mm diameter (750 MCM or 2-500 MCM)
• 1000 A ac and dc current measurement
• 2500 A ac current measurement with iFlex flexible current probe
• 1000 V ac and dc voltage measurement
• True-rms voltage and current for accurate measurements on non-linear signals
• Frequency measurement to 500 Hz with body jaw and iFlex
• Resistance measurement to 60 kΩ with continuity detection
• Min, max, average, and inrush recording to capture variations automatically
• 500 mV dc measurement range to interface with other accessories
• 1000 μF capacitance measurement
• Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
• Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
• iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
• TPAK magnetic hanging strap (included)
• Integrated VFD low pass filter for accurate motor drive measurements
• Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
• CAT IV 600 V, CAT III 1000 V safety rating
• 2500 A ac current measurement with iFlex flexible current probe
• 1000 V ac and dc voltage measurement
• True-rms voltage and current for accurate measurements on non-linear signals
• Frequency measurement to 500 Hz with body jaw and iFlex
• Resistance measurement to 60 kΩ with continuity detection
• Min, max, average, and inrush recording to capture variations automatically
• 500 mV dc measurement range to interface with other accessories
• 1000 μF capacitance measurement
• Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
• Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
• iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
• TPAK magnetic hanging strap (included)
• Integrated VFD low pass filter for accurate motor drive measurements
• Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
• CAT IV 600 V, CAT III 1000 V safety rating
Supplied with
18in iFlex current probe, test leads, soft carry case, 2 x AA alkaline batteries and instructions
Attribute | Value |
---|---|
Absolute Maximum AC Current Measurement | 2.5kA ac |
Absolute Maximum DC Current Measurement | 999.9A dc |
Absolute Maximum AC Voltage Measurement | 1000V ac |
Absolute Maximum DC Voltage Measurement | 1000V dc |
Absolute Maximum Resistance Measurement | 60kΩ |
Model Number | 376 |
AC Current Measurement Resolution | 100mA ac |
DC Current Measurement Resolution | 100mA dc |
Best DC Current Accuracy | ±2% + 5 Digits |
Clamp Meter Type | Capacitance, Continuity, Current, Frequency, Resistance, Voltage |
Best AC Current Accuracy | ±2% +5 digits |
Best AC Voltage Accuracy | ±1.5% + 5 Digits |
True RMS | Yes |
Best DC Voltage Accuracy | ±1% + 5 Digits |
Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance |
AC Voltage Measurement Range | 1000 V ac |
Display Type | LCD |
Maximum Conductor Size | 34mm |
Best Resistance Measurement Accuracy | ±1% + 5 Digits |
Safety Category | CAT III 1000 V, CAT IV 600 V |
Battery Type | AA |
Power Source | Battery |
DC Voltage Measurement Resolution | 0.1V dc |
Resistance Measurement Resolution | 100mΩ |
Length | 248mm |
Safety Category Level | CAT II, CAT IV |
Safety Category Voltage | 600 V, 1000 V |
Width | 85mm |
DC Current Measurement Range | Maximum of 999.9 A dc |
Dimensions | 248 x 85 x 45mm |
Minimum Operating Temperature | -10°C |
Height | 45mm |
AC Voltage Measurement Resolution | 0.1V ac |
AC Current Measurement Range | Maximum of 2500 A ac |
Weight | 375g |