2 Channel Zener Barrier With Analogue Output, 250 V max, 120mA max

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
Product Details

Z787.H Dual Channel

The solution for applications with 3-wire transmitters is implementing a combination of one 28V, 300Ω and one 28V barrier with diode return. Special consideration should be given to the internal voltage drop due to the diode return.,Typical application - 4-20mA transmit

//media.rs-online.com/t_line/L280658-01.gif
//media.rs-online.com/t_line/L280658-02.gif

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G

Specifications
Attribute Value
Barrier Type Zener
Number of Channels 2
Supply Voltage 28 V dc
Safety Voltage Maximum 250 V
Safety Current Resistance 250Ω
Safety Current Maximum 120mA
Signal Type Analogue
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Hazardous Area Certification ATEX
Operating Temperature Range -20 → +60 °C
17 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 712.38
units
Per unit
1 +
MYR712.38
Related Products
Input contacts can be used in any explosive ...
Description:
Input contacts can be used in any explosive gas and Zone 0/Class I Div. 1 areas. Explosion protectionRelay Barrier: (Exia) II CSwitch (EB9Z-A): Exia II CT6Switch (EB9Z-A1): Exia II BT6Compact and lightweight (46% footprint and 36% weight compared to IDEC’s ...
Zener barriers provide cost saving Ex-protection for various ...
Description:
Zener barriers provide cost saving Ex-protection for various applications in process automation systems. The amount of energy transferred to the hazardous location is limited to a safe level incapable of igniting the explosive atmosphere. Typical application - transmitters, transducers, solenoid ...
Standard DIN rail mountRemovable, colour-coded terminalsBussed power feed ...
Description:
Standard DIN rail mountRemovable, colour-coded terminalsBussed power feed to other modulesRelay and solid state switch modulesDual channel variants - 6.3mm per channelProximity detector inputsDirect replacement for MTL700 SeriesCompatible terminal numbering and safety descriptionsDimensions: 105 x 90 x 12.6mm.
The MTL5500 series is the latest generation of ...
Description:
The MTL5500 series is the latest generation of MTL isolators. Incorporating advanced circuit design and innovative isolating transformer construction. The compact 16mm wide design reduces weight and gives a high packing density and reduction in power consumption. They build on ...