Various Thermocouple Input Temperature Transmitter, 9 → 30 V dc

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DK
Product Details

6350B- Profibus PA/Foundation Fieldbus Transmitter

PR Electronics 6350B intrinsically safe programmable temperature transmitter offers unrivalled performance in applications making heavy demands on accuracy to convert a wide array of input types to a PROFIBUS PA and FOUNDATION Fieldbus communication signal. The 6335 transmitters provides unrivalled input versatility with galvanic isolation up to 1.5 kVAC. Virtually any thermocouple or 2, 3 & 4 Wire RTD, plus linear resistance and bipolar mV signals. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure.
The 6300 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes.

Features and Benefits

• DIN Rail mounting
• Galvanic isolation
• Can be installed in Ex zone 0
• Sensor drift detection maintains measuring point reliability
• Flexible input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz–100 MHz
• Continuous check of vital stored data for safety reasons
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions

Temperature Transmitters

4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software

Specifications
Attribute Value
Input Type Current, Linear Resistance, Potentiometer, RTD, Thermocouple, Voltage
Supply Voltage 9 → 30 V dc
Diameter 23.5 (Width) mm
Minimum Temperature Input -200°C
Maximum Temperature Input 850°C
Minimum Operating Temperature -40°C
Maximum Operating Temperature +85°C
Series 6300
Depth 104mm
Hazardous Area Certification ATEX
Temporarily out of stock - back order for despatch when stock is available
Price Each
MYR 2,940.87
units
Per unit
1 +
MYR2,940.87
Related Products
2-wire programmable transmitter can be programmed to measure ...
Description:
2-wire programmable transmitter can be programmed to measure temperatures within all TC ranges defined by the standards and has a high measurement accuracy. TC InputGalvanic IsolationProgrammable sensor error value1 (136-8671) or 2 (136-8675) channel options availableDIN Rail mounting (vertically or ...
2-wire HART transmitter is designed according to strict ...
Description:
2-wire HART transmitter is designed according to strict safety requirements and is suitable for applications in SIL installations. 2 Analogue inputs and 5 device selectable variables with status availableHART protocol revision selectable from HART 5 or HART 71 (136-8680) or ...
RTD, TC, potentiometer, linear resistance and bipolar mV ...
Description:
RTD, TC, potentiometer, linear resistance and bipolar mV inputSingle or true dual inputs with sensor redundancy and drift detectionHigh accuracy across a wide ambient operating temperature of -50 to +85°C2.5 kVAC galvanic isolationApplication:Temperature measurement of a wide range of TC ...
4 to 20mA loop powered output and reverse ...
Description:
4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software. Digital in-head transmitterPush button configuration in less than 10 secs Drift free digital technologyOperating Temperature Range: 0°C to +70°CDimensions: H21mm x ...