Sensata / Crydom 5 A SPST Solid State Relay, DC, DIN Rail, MOSFET, 48 V dc Maximum Load

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): MX
Product Details

Plug In, DIN / PCB Mount - ED Series

The DC switching ED series from Crydom offers a DC output solid state relay series in an industry standard
EMR plug in package. This enables the device to be both mounted onto a PCB (via RS stock number 740-1365) or a standard DIN rail (via RS stock number 740-1368).

DC output solid state relay in an industry standard EMR plug in package
Ratings of 5 Amps
Load voltage range of 1 → 48 and 1 → 80 Vdc
Fits standard DIN rail & PCB mountable sockets
LED input status indicator
AC or DC control voltage available
cUL recognised, IEC rated, CE & RoHS compliant
Motor controller rated

Approvals

cUL, IEC, CE, CCC & RoHS compliant

Approvals

cUL, IEC, CE

DC Switching

Specifications
Attribute Value
Minimum Load Current 0.1 A
Maximum Load Current 5 A
Mounting Type DIN Rail
Minimum Load Voltage 1 V dc
Maximum Load Voltage 48 V dc
Minimum Control Voltage 5 V dc
Maximum Control Voltage 15 V dc
Switching Type DC
Contact Configuration SPST
Terminal Type Through Hole
Output Device MOSFET
Package Style EMR
Maximum Turn On Time 0.6 ms
Dimensions 29 x 12.7 x 37.4mm
Operating Temperature Range -30 → +80°C
Off State Leakage Current 20 μA
Height 37.4mm
Minimum Operating Temperature -30°C
Length 29mm
Load Voltage Range 1 → 48V dc
Depth 12.7mm
Maximum Operating Temperature +80°C
Control Voltage Range 5 → 15 V dc
112 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 90.38
units
Per unit
1 +
MYR90.38
Related Products
The pin assignment for SIM-EI miniature opto-couplers is ...
Description:
The pin assignment for SIM-EI miniature opto-couplers is compatible with G2R (Omron) and RT (Schrack) type relays with 5 mm pins.They may be used in place of electro-mechanical relays to convert signals from sensor units.
The Telefast 2 system of pre-cabling is composed ...
Description:
The Telefast 2 system of pre-cabling is composed of modules connected to the PLC by means of a multicore cable equipped with HE 10 connectors . The Telefast 2 interfaces make it possible to simplify the operation of wiring and ...
Universal Series can be used as either an ...
Description:
Universal Series can be used as either an input or an output device. Connection of sensors/actuators is via modular terminal blocks. Feather-light direct connection of conductors starting from 0.34 mm2 without tools. The connection of small cross sections from 0.14 ...
6.2mm DIN-rail mount (35 mm) SSR assemblyRatings 24Vdc ...
Description:
6.2mm DIN-rail mount (35 mm) SSR assemblyRatings 24Vdc at 3.5A, 48Vdc at 100mA and 240Vac at 2A5 and 24 Vdc and 120V and 240 Vac control voltageUL and cUL recognised at 40°C, 100K-cycle endurance testYellow LED input status indicator.