Burkert Solenoid Valve 134087, 2 port , NC, 230 V ac, M5

  • RS Stock No. 313-1961
  • Mfr. Part No. 134087
  • Manufacturer Burkert
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

6011 Series Two-Way, Miniature Normally Closed Solenoid Valves - Threaded Port Connection

Coil changed easily with valve in place
Coil can be locked in four 90° positions or move free between, as required
Brass body, polyamide coil and FPM high quality seal material
Suitable for compressed air, water, hydraulic oil
Operating temperature -10 to +100°C max.
Power consumption 4W DC; 9VA (Inrush); 6VA (Hold)
Protection to IP65 with cable plug DIN43650C

//media.rs-online.com/t_line/L313194-01.gif
//media.rs-online.com/t_line/L439060-04.gif
//media.rs-online.com/t_line/L439240-02.gif
//media.rs-online.com/t_line/LI313194-01.gif
//media.rs-online.com/t_line/LI313194-02.gif

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left-hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and is described on the right-hand side of the diagram. The 3 / 2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2 / 2-way valves as two ways. The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications indicates the appropriate connections and pressure capabilities when an alternative circuit function is required.

Specifications
Attribute Value
Supply Voltage 230 V ac
Number of Ports 2
Operation Direct
Connection M5 Metric Female
Connection Size M5
Default Valve Position NC
Suitable Applications Liquid, Neutral Gas, Technical Vacuum
Type 2/2
Orifice Diameter 1.2mm
Body Material Brass
Maximum Working Pressure 21 bar
Operating Temperature Range Maximum of +55 °C
Maximum Operating Temperature +55°C
Connection Gender Female
Flow Factor Kv 0.045m³/h
Maximum Closing Time 15ms
Thread Standard or Connection Type Metric
Series 6011
Maximum Opening Time 10ms
12 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 206.50
units
Per unit
1 - 5
MYR206.50
6 - 11
MYR199.96
12 +
MYR197.22
Related Products
Two-way, direct acting solenoid valves, normally closed with ...
Description:
Two-way, direct acting solenoid valves, normally closed with threaded port connection. Brass bodyPressure not required for operationCompact & lightweightDIN plug connectionRanging from -10°C to +100°C Can be mounted in any position.
Two-way, pilot operated solenoid valves, minimum operating pressure ...
Description:
Two-way, pilot operated solenoid valves, minimum operating pressure required, normally closed with threaded port connection. Brass bodyMinimum operating pressure requiredCompact & lightweightDIN plug connection Ranging from -20 to +85°CCan be mounted in any position.
Two-way, direct operated, EN161 approved solenoid valves for ...
Description:
Two-way, direct operated, EN161 approved solenoid valves for use on gas pilot and gas burner control, zero bar minimum operating pressure, normally closed, threaded port connection. Pressure not required for operationCompact & lightweightISO 4400 DIN connectionClass A, group 2 service ...
Two-way, pilot operated solenoid valves for hot water/steam ...
Description:
Two-way, pilot operated solenoid valves for hot water/steam applications, normally closed with threaded port connection. Brass bodyCompact design to minimize heat radiation lossDIN plug connection Ranging from -20 to +184°CCan be mounted in any position.