Mersen 16A A1 Slotted Tag Fuse, gG, 250 V dc, 550 V ac

  • RS Stock No. 178-0996
  • Mfr. Part No. C1019224
  • Manufacturer Mersen
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IN
Product Details

These fuses are designed for : “General purpose use” protection (gG type) or motor protection (gM type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by other fuses of higher rating in their range. They are screwed into fuseholders or bolted directly onto busbars, or in fuse interruptors disconnectors

Specifications
Attribute Value
Fuse Standard BS 88, IEC 60269
Fuse Size A1
Current Rating 16 A
Voltage Rating 250 V dc, 550 V ac
High Rupture Capacity No
Body Diameter 13.5mm
Overall Length 56mm
Tag Width 11.2mm
Body Height 35.5mm
Fixing Centres 44.5mm
Application Category GG
Fuse Dimensions 13.5 x 35.5mm
Tag Orientation Offset
Tag Type Blade
110 In Global stock for delivery within 4 - 6 working days
Price Each (In a Pack of 10)
MYR 10.589
units
Per unit
Per Pack*
10 - 40
MYR10.589
MYR105.89
50 - 90
MYR9.656
MYR96.56
100 +
MYR8.908
MYR89.08
*price indicative
Related Products
Schurter UMT fuses offer primary protection on SMD ...
Description:
Schurter UMT fuses offer primary protection on SMD PCB's. There are several applications that are suited to the performance characteristics of the UMT SMD fuse. These applications include industrial electronic, sensors, power supplies, explosion protection and lighting. Surface MountHigh current ...
These fuses are designed for : “General purpose ...
Description:
These fuses are designed for : “General purpose use” protection (gG type) or motor protection (gM type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by ...
Cooper Bussman's bolted tag fuse is essentially a ...
Description:
Cooper Bussman's bolted tag fuse is essentially a fuse that is fitted with brackets, these brackets allow the fuse to be bolted onto a fuse holder. Predominantly, this type of fuse is used within installations as a "weak link". They ...
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating. e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity ...