Omron Configurable 19.2 → 28.8 V dc Safety Relay Dual Channel With 2 Safety Contacts

  • RS Stock No. 860-3770
  • Mfr. Part No. G9SR-AD201-RC
  • Manufacturer Omron
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): NL
Product Details

Omron G9SR Configurable Safety Relay

The three models of the Omron G9SR safety relays cover virtually all common control system safety requirements in standalone applications. They feature front-panel DIP switches for fast, easy configuration and customization, together with LED indicators for quick status monitoring and fault diagnosis.
The key characteristics of the G9SR include certification to category PLe in line with EN/ISO 13849-1, fast response time to ensure minimum stopping times, solid-state outputs for long-life wear-free operation, compact housings to save space in control panels and removable spring-type terminals to ensure rapid straightforward installation. All units are equipped with an additional monitoring output to provide diagnostic information for use by the standard control system.

G9SR Series Basic Unit.

The G9SR Basic Unit is just 17.5 mm wide and has single or double channel safety inputs, plus double channel solid state safety outputs. The outputs are rated at 2A, which makes them suitable for direct switching of even large contactors.

Features and Benefits.

Compatible for a variety of safety solutions like E-Stop, guard monitoring devices, light curtains and others
Fast response time for short safety distance
Semiconductor outputs for wear-free operation
DIP-switch configurable for fast setup/customized function
Removable spring-type terminals for fast installation
Certified to PLe category (EN/ISO 13849-1) standards Basic Unit Stock number 8603773. 2P ch MOSFET.

G9SR Series Advanced Unit.

The G9SR Advanced Unit is 22.5 mm wide and has single or double channel safety inputs, plus double channel safety relay outputs rated at 5 A. For applications where input expansion is needed, each advanced unit can control up to two G9SR basic units that are configured as additional safety inputs to the same safety function.

Features and Benefits.

Compatible for a variety of safety solutions like E-Stop, guard monitoring devices, light curtains and others
Safety relay outputs with 5A loading
DIP-switch configurable for fast setup/customized function
Removable spring-type terminals for fast installation
Control centre for input/output extension modules
Certified to PLe category (EN ISO 13849-1) standard Advanced units stock number 8603770. 2 PST-NO (normally open)

G9SR Series Extension Unit.

The G9SR Extension Unit is 22.5 mm wide and has three safety relay outputs rated at 5 A. These outputs can be configured for instantaneous operation or to provide independent safe on and off delay timers that can be set in sixteen steps to give a maximum delay of 90 seconds. Up to three G9SR output expansion units can be connected to an advanced unit to provide one instantaneous safety output on the advanced module plus three time controlled safety outputs on the extension units.

Specifications
Attribute Value
Supply Voltage 19.2 → 28.8 V dc
Number of Channels 2
Function Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Safety Contacts 2
Terminal Type Cage Clamp
Length 114.5mm
Depth 22.5mm
Width 99mm
8 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 679.81
units
Per unit
1 +
MYR679.81
Related Products
Detects the stop condition of all types of ...
Description:
Detects the stop condition of all types of AC or DC motor driven machines which, when the motor runs down, produce a residual voltage in the windings. No additional sensor is required1 N/O and 1 N/C contacts, EN954-1 Category 3 ...
Safety relay for emergency stop, safety doors, 1- ...
Description:
Safety relay for emergency stop, safety doors, 1- or 2-channel operation, cross-circuit detection, can be retriggered, fall back/tightening delay 0.2 s to 60 s, 2 enabling current paths, US = 24 V DC, plug-in spring-cage terminal block. Low housing width ...
For use in controls of metal working presses ...
Description:
For use in controls of metal working presses and other processing machines with dangerous lock movements (conforms to EC directive for machines 89/392/EEC, safety regulations for two-hand circuits on ZH 1-456 power-driven metal work presses). IV quality level compliant with ...
XPS-MP offers a simple solution for all safety ...
Description:
XPS-MP offers a simple solution for all safety applications and reduces the number of ordering references needed by combining 15 pre-determined functions that are all certifiedDesigned to monitor 2 safety functions independently, choose from; emergency stop, protective door locking, 2 ...