Omron 24 V dc Safety Relay Dual Channel Compatible With Safety Switch/Interlock

  • RS Stock No. 757-9320
  • Mfr. Part No. G9SX-GS226-T15-RT DC24
  • Manufacturer Omron
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

G9SX-GS, Safety Relays, Guard Switching

The G9SX-GS safety relay is designed to support maintenance mode and normal operation mode in a safe way.

Two operation modes to support auto switching for applications where machine and worker co-operate and manual switching for applications with limitations in operation such as machine maintenance
Clear LED diagnosis of all inputs and outputs
Applicable up to Category 4 acc. EN 954-1

Standards

EN 954-1

G9SX-GS Safety Guard Relay Switching Module.

• Two functions supporting two types of application.
• Auto-switching. Where operators work along with machines.
• Manual switching. Applications with limited operations.
• External indicator outputs indicating the switching status of two safety input devices.
• Auxiliary outputs allow monitoring of safety inputs, outputs, errors.
• LED indicators for easy diagnosis.
• Logical and connections for difficult applications along with other G9SX series.

G9SX-GS226-T15-RT DC24 Safety Guard Switching Unit.

• Safety outputs. P channel MOS-FET output.
• Instantaneous – 2 semi-conductor.
• OFF-delayed 2 semi-conductor. (instantaneous output by setting OFF-delay time to 0 s).
• Auxiliary outputs 6 semi-conductor. PNP transistor output – except for external indicator outputs, they are P channel MOS-FET outputs.
• Logical AND connections 1 semi-conductor input and output.
• Max OFF delayed time 15 s.
• Time OFF set in 16 steps (0, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 1, 1.5, 2, 3, 4, 5, 7, 10 or 15 s)
• Rated voltage 24 V dc.
• Screw terminal block.

Features and Benefits.

• Rated supply voltage 24 V dc.
• Operating voltage range -15% to 10% of sated supply voltage.
• Power consumption 5 W max.
• Input operating voltage 20.4 V dc to 26.4 V dc, Internal impedance approx. 2.8 kΩ
• Instantaneous safety outputs P channel MOS-FET
• OFF-delayed safety outputs load current 0.8 A dc max (derating required when mounted side by side 0.4 A max load)
• Auxiliary outputs PNP transistor (load current 0.8 A dc max output max) (derating required when mounted side by side 0.4 A max load)
• External indicator outputs P channel MOS-FET, connectable indicators, 24 V dc, 3 to 7 W Incandescent lamp. LED lamp 10 to 300 mA dc output.
• Overvoltage category II.
• Operating time OFF to ON state 50 ms max (safety input ON), 100 ms max (Logical AND connection input ON).
• Response time (ON to OFF state) 15 ms max
• Maximum wiring length of safety input and logical AND input 100 m max.
• Vibration resistance frequency 10 to 55 to 10 Hz, 0.375mm single amplitude (0.75 mm double amplitude).
• Shock resistance destruction 300 m/s².
• Shock resistance malfunction 100 m/s².
• Electrical durability 100,000 cycles min.
• Mechanical durability 5,000,000 cycles min.
• Weight 240 g.

Applications.

• Safety measure for hazardous operations maintaining productivity.
• Auto-switching function, safety light curtain.
• Manual switching function, door switch monitors.

Standards

IEC/EN 61508 (SIL3), IEC/EN 62061 (SIL3), EN ISO 13849-1 (PLe/safety category 4)

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Function Safety Switch/Interlock
Terminal Type Screw
Length 100mm
Width 45.5mm
Depth 115mm
2 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 2,853.19
units
Per unit
1 +
MYR2,853.19
Related Products
M2000 2 and 3 beam devices are used ...
Description:
M2000 2 and 3 beam devices are used for perimeter and access guarding where risk assessment shows that a category 2 device (according to EN 954) offers a suitable level of safety. The M2000 is a Type 2 IEC 61508 ...
The G9SA family offers a line-up of compact ...
Description:
The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the ...
Suitable for applications that require a safe timing ...
Description:
Suitable for applications that require a safe timing sequenceMeet all requirements of the currently valid safety standards EN 62061, EN ISO 13849-1, Cat 4, SIL 3, PL eCan be used as emergency stop and safety gate monitorSingle-channel or two-channel activation ...
LED indication for supply voltage and safety circuitsAutomatic ...
Description:
LED indication for supply voltage and safety circuitsAutomatic restart function availableContact current rating: 6A Conform to BS EN 60204 Part 1 1993; EN 954-1; IEC 204-1; VDE 0113 Dimensions (mm): H 96.5, W 22.5, L 114.