Schneider Electric 24 V dc Safety Relay With 2 Safety Contacts and 4 Auxilary Contact

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

XU2 S, Type 2, Single Beam System

The XPS-CM safety module, used in conjunction with the single beam XU2S safety light devices, constitutes a type 2 safety light curtain conforming to IEC 61496-1.

Flexibility allows connection of up to 4 light beam devices which can protect a zone up to 1200mm high and 8m wide (EN999)
Automatic self-checking every 5ms
Built in muting function allows the light device to be inhibited by an external sensor
Single beam sensors (for muting function) available separately
Ideal for transfer line applications
Solid state auxiliary output (from module) PNP 20mA/24Vdc
2 N/O safety outputs

Note

This product is supplied with a full installation instruction manual which should be strictly adhered to. Particular attention should be given to section 3.5 (installation positioning and electrical inter-phasing).

Single Beam Safety Device

Specifications
Attribute Value
Supply Voltage 24 V dc
Auxiliary Contacts 4
Function Light Beam/Curtain
Safety Contacts 2
Range Preventa
Terminal Type Screw
5 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 1,570.75
units
Per unit
1 - 5
MYR1,570.75
6 +
MYR1,524.06
Related Products
Protection relay with probe, LT3 series, that permanently ...
Description:
Protection relay with probe, LT3 series, that permanently controls the temperature of machines that require protection (motors, alternators etc..). Operates via CTP thermistor probes.Automatic or manual reset.Faults displayed on the front panel of the device or remotely, except for version ...
Detects the stop condition of all types of ...
Description:
Detects the stop condition of all types of AC or DC motor driven machines which, when the motor runs down, produce a residual voltage in the windings. No additional sensor is required1 N/O and 1 N/C contacts, EN954-1 Category 3 ...
Relay module with driven contacts, Nominal input voltage: ...
Description:
Relay module with driven contacts, Nominal input voltage: 24 VDC, 2 changeover contacts, Limiting continuous current: 8 A, Red status indicator, Module width: 15 mm. Reinforced insulation between coil and contactsA separator plate (e.g., 209-191) must be used for voltages ...
Relay module, Nominal input voltage: 24 VDC, 2 ...
Description:
Relay module, Nominal input voltage: 24 VDC, 2 changeover contacts, Limiting continuous current: 8 A, Green status indicator, Module width: 15 mm. Reinforced insulation between coil and contactsA separator plate (e.g., 209-191) must be used for voltages greater than 250 ...