Schneider Electric 24 V dc Safety Relay Dual Channel With 2 Safety Contacts 2 Auxilary Contacts

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ID
Product Details

XPS VNE, Zero Speed Detection

Detects the stop condition of all types of AC or DC motor driven machines which, when the motor runs down, produce a residual voltage in the windings. No additional sensor is required
1 N/O and 1 N/C contacts, EN954-1 Category 3 / EN 13849-1
2 solid-state outputs for signalling to PLC
4 LEDs for status signalling
Maximum motor voltage: 500Vac
2 potentiometers mounted on the front face of the module allow independent adjustment of the switching threshold for each input circuit. This allows adjustment for different types of motors and application requirements
45mm housing
Pull off terminals for a simple and quick maintenance

Note

Standard module (stock no 464-485) is designed for frequencies up to 60Hz. For motors operating at a frequency higher than 60Hz producing a high frequency remnant voltage, stock no 464-489 should be used

Specifications
Attribute Value
Supply Voltage 24 V dc
Number of Channels 2
Auxiliary Contacts 2
Function Speed/Standstill Monitoring
Safety Contacts 2
Range Preventa
Terminal Type Screw
Length 120mm
Width 45mm
Depth 99mm
4 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 2,504.30
units
Per unit
1 +
MYR2,504.30
Related Products
2 N/O instantaneous outputs provide stop category 0, ...
Description:
2 N/O instantaneous outputs provide stop category 0, 3 N/O timed contacts provide stop category 1 by allowing controlled deceleration of the motor until a complete stop is achieved4 solid state outputs for PLC signallingMonitored start button featureDelay time: 0 ...
Suitable for applications that require a safe timing ...
Description:
Suitable for applications that require a safe timing sequenceMeet all requirements of the currently valid safety standards EN 62061, EN ISO 13849-1, Cat 4, SIL 3, PL eCan be used as emergency stop and safety gate monitorSingle-channel or two-channel activation ...
Stop-Category 0 acc. EN 60204-1Applications up to Category ...
Description:
Stop-Category 0 acc. EN 60204-1Applications up to Category 4 acc. EN 954-1, to SIL 3 according to EN62061 and PL e according to EN13849-1Can be used as emergency stop and safety gate monitorManual reset with self-monitoring on each ON-OFF cycleCross ...
The PSR safety relay is for two-hand control ...
Description:
The PSR safety relay is for two-hand control devices and safety door circuits. Relevant safety equipment can be connected easily without the need for additional settings on the relay. Two-channel controlAutomatic activationFor two-hand control devices as per EN 574 type ...