Siemens 4 Pole Type B Residual Current Circuit Breaker, 25A 5SM3, 300mA

  • RS Stock No. 621-9957
  • Mfr. Part No. 5SM3642-4
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Series 5SM3, Type B SEQUENCE, 4-pole

All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currents
Increased operating reliability in networks with capacitive impedances based on adapted actuation characteristic
Switch handle and test button may be locked via handle lock
Time-delayed disconnect function in the event of transient stray currents
High current capacity < 3 kA

Applications:

Systems with consumers in which smooth residual DC currents may also occur
Use in three-phase systems

Standards

IEC / EN 61008-1, IEC / EN / 61543

Approvals

VDE 0664 Part 10, VDE 0664 Part 100, VDE 0664 Part 30

Siemens FI circuit breaker

Specifications
Attribute Value
Current Rating 25A
Range Sentron
Number of Poles 4
Trip Sensitivity 300mA
Tripping Characteristics Type B
Voltage Rating 400V
Series 5SM3
2 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 4,076.58
units
Per unit
1 +
MYR4,076.58
Related Products
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units. Manufactured to BS EN 61009Flying lead neutral cable for easy installationType B MCB and 30mA RCD combined in one device10kA MCB/RCBO breaking capacityType B MCB/RCBO operating characteristic.
These devices complement our range of MK Series ...
Description:
These devices complement our range of MK Series enclosures. Manufactured to BS EN 61009 Type B MCB and 30mA RCD combined in one deviceFlying leads for easy installationPositive contact status indicationOne module wide.
The RCCBs F200 series assures protection against the ...
Description:
The RCCBs F200 series assures protection against the effects of sinusoidal alternating and direct pulsating earth fault currents, protection, against indirects contacts and additional protection against direct (with sensitivity = 30 mA) contacts. Applications: residential, commercial, industrial. This particular ...
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating. VisiTrip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtimeInsulation Voltage: 440 VacVoltage: ...