ABB 2 Pole Type B Residual Current Circuit Breaker, 40A F200, 30mA

  • RS Stock No. 176-9607
  • Mfr. Part No. F202B-40/0.03
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

ABB Residual Current Circuit Breaker

The ABB F200 series residual current circuit breaker is a 2-pole type B device. It has an electrical rating of 230V and 40A. The operation of the residual circuit breaker is indicated using a green LED. This circuit can operate in extremely harsh weather conditions up to 60°C.

Features and Benefits

• Breaking maximum voltage rating is 10KA
• Compact design
• DIN rail type mounting
• Earth fault safety protection
• Operation temperature ranges in between -25°C and 55°C
• Trip sensitivity is 30mA

Applications

• Faulty electronic circuits
• Industrial application

Certifications

• DIN
• EN 62423
• IMQ
• VDE

Specifications
Attribute Value
Current Rating 40A
Number of Poles 2
Trip Sensitivity 30mA
Tripping Characteristics Type B
Voltage Rating 230V
Series F200
Overall Depth 85mm
Overall Width 69mm
Breaking Capacity at Maximum Voltage Rating 10 kA
Break Time Time Delay
Mounting Style DIN Rail Mount
Overall Dimensions 35 x 69 x 85mm
Circuit Breaker Type RCCB
Special Features Earth Fault Safety Protection
Earth Leakage Protection Type F
Overall Length 35mm
Reset Actuator Type Toggle Switch
Terminal Contact Type Screw
1 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 3,492.37
units
Per unit
1 +
MYR3,492.37
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Range of plug-in circuit breakers for assembly on ...
Description:
Range of plug-in circuit breakers for assembly on Distri'clic XE splitters.Control and protection of single-phase circuits downstream of the connecting circuit breaker, for "blue tariff".Standard C graph.The magnetic circuit breakers work between 5 and 10In.Supply voltage 230Vac.Breaking capacity 3kA according ...
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
Type F RCDs offer the same range of ...
Description:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according ...