ABB 2 Pole Type B Residual Current Circuit Breaker, 25A F200, 30mA

  • RS Stock No. 176-9606
  • Mfr. Part No. F202B-25/0.03
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

Details that make the difference:

Type B residual current devices are marked according to EN 62423.
Easy to connect and compatible with busbars thanks to the System pro M compact clamps.
Sole two-pole device in only two modules on the market.
VDE approved.
Green LED to monitor operation of the residual current circuit breaker.
Indication of the position of the contacts.

Compact and functional design
The new F200 B RCCBs feature an innovative design that makes the products compact. Indeed, the two-pole device is the first one on the market that is built in just two modules and its compact dimensions ensure significant space savings in the switchboard. The new range of F200 B RCCBs is certified by the IMQ and VDE markings for operation in extremely harsh weather conditions up to 60 °C.

F202 B-25/0,03 Residual Current Circuit Breaker

Specifications
Attribute Value
Current Rating 25A
Number of Poles 2
Trip Sensitivity 30mA
Tripping Characteristics Type B
Voltage Rating 230V
Series F200
Overall Width 69mm
Overall Depth 85mm
Reset Actuator Type Toggle Switch
Special Features Earth Fault Safety Protection
Earth Leakage Protection Type F
Overall Dimensions 35 x 69 x 85mm
Circuit Breaker Type RCCB
Breaking Capacity at Maximum Voltage Rating 10 kA
Break Time Time Delay
Overall Length 35mm
Terminal Contact Type Screw
Mounting Style DIN Rail Mount
25 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 3,408.18
units
Per unit
1 +
MYR3,408.18
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
Range of plug-in circuit breakers for assembly on ...
Description:
Range of plug-in circuit breakers for assembly on Distri'clic XE splitters.Control and protection of single-phase circuits downstream of the connecting circuit breaker, for "blue tariff".Standard C graph.The magnetic circuit breakers work between 5 and 10In.Supply voltage 230Vac.Breaking capacity 3kA according ...
The ABB F200 RCCB Series provide ground fault ...
Description:
The ABB F200 RCCB Series provide ground fault protection by monitoring the leakage of current to ground when used in conjunction with standard MCBs. The F200 series are compact DIN rail mounted RCCBs and feature a wide range of trip ...