Parker 3 → 8bar 0.1 → 30s Pneumatic Timer, -15 → +60°C

  • RS Stock No. 410-488
  • Mfr. Part No. PRT-C10
  • Manufacturer Parker
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Very Reliable
Long Life Expectancy

Note

All logic units require mounting on a separate 2 or 3 port base, available separately. Logic units have an input (green) and output (red) pressure indicator to show the state of the respective signal. Units are supplied with two captive screws for mounting on all types of base and sealing o-rings are in the bottom of each unit.

//media.rs-online.com/t_line/L267136-01.gif
//media.rs-online.com/t_line/L267136-02.gif
//media.rs-online.com/t_line/L267136-03.gif
//media.rs-online.com/t_line/L267137-01.gif

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Specifications
Attribute Value
Manufacturer Series PRT
Minimum Operating Pressure 3bar
Maximum Operating Pressure 8 bar
Minimum Operating Temperature -15°C
Maximum Operating Temperature +60°C
Minimum Time 0.1s
Maximum Time 30s
Temporarily out of stock - back order for despatch 04/02/2020, delivery within 4 working days from despatch date
Price Each
MYR 773.62
units
Per unit
1 +
MYR773.62
Related Products
Combination of adjustable orifice and fixed flow allows ...
Description:
Combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Bracket and Panel mounting.
On application of a pilot signal the reservoir ...
Description:
On application of a pilot signal the reservoir starts to fill via the low restrictor. After the set time delay the relay is operated and an output is given. The timer will not reset until the pilot signal is removed. ...
An adjustable single impulse generator which transforms a ...
Description:
An adjustable single impulse generator which transforms a maintained signal into a single pulse of adjustable durationWhen an input signal is applied the output is switched on via the negative output relay. At the same time the reservoir starts to ...
Provides an adjustable time delay between successive operations ...
Description:
Provides an adjustable time delay between successive operations in a sequence. Ideal for use in hazardous environments.Automatic reset.