12V ac 2 Output Through Hole PCB Transformer, 14VA

  • RS Stock No. 201-7189
  • Mfr. Part No. FL 14/12
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mounting Low Profile 115 / 230Vac Primary

Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection
Twin secondary windings for series or parallel connection
Low profile compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure board mounting
Standard: EN60742, VDE 0551, IEC 61558

Note

Transformer with 2 x 24V outputs are not VDE, SEV approved.

Standards

VD 61 558

//media.rs-online.com/t_line/L201683-01.gif

Approvals

VDE; UL

Standards

VD 61 558

Specifications
Attribute Value
Secondary Voltage Rating 12V ac
Power Rating 14VA
Primary Voltage Rating 115V ac, 230V ac
Number of Outputs 2
Length 68mm
Width 24.4mm
Depth 57mm
Dimensions 68 x 24.4 x 57mm
Weight 315g
Mounting Type Through Hole
Maximum Temperature +40°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
19 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 81.22
units
Per unit
1 - 9
MYR81.22
10 - 24
MYR75.33
25 - 49
MYR69.46
50 - 99
MYR66.56
100 +
MYR66.29
Packaging Options:
Related Products
Compact, open type control panel transformerFully shrouded screw ...
Description:
Compact, open type control panel transformerFully shrouded screw terminals with permanent markingDetailed product specification permanently marked on front of unitVA ratings compatible with available protection devicesDual standard primary winding 230 / 400Vac.
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.