18V ac 2 Output Through Hole PCB Transformer, 2.5VA

  • RS Stock No. 173-9822
  • Mfr. Part No. 44167
  • Manufacturer Myrra
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Type EI 30 - 1 VA → 2.3 VA series 44000 transformers

From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable.

Features and Benefits:

• Professional safety transformers with insulation above 4000V.
• For installation on printed circuit boards (according to European grid).
• Coupling in series or parallel.
• Vacuum-filled with resin to ensure materials withstand aging.
• Unit and 100% control on automated line.
• Secondary voltages are nominal load voltages on resistive loads.

Standards

UL 94-V0; VDE 0551; IEC 742

Approvals

UL, VDE

Encapsulated – Toroidal

Note

Fixing screws not provided

Specifications
Attribute Value
Secondary Voltage Rating 18V ac
Power Rating 2.5VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 32.6mm
Width 27.6mm
Depth 29.8mm
Dimensions 32.6 x 27.6 x 29.8mm
Weight 70g
Mounting Type Through Hole
Maximum Temperature +70°C
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
2 Within 4 working day(s) (Global stock)
66 Within 4 working day(s) (Global stock)
Price Each
MYR 22.90
units
Per unit
1 - 24
MYR22.90
25 - 49
MYR20.22
50 - 99
MYR15.09
100 - 249
MYR14.02
250 +
MYR13.38
Related Products
Multi-tapped secondary winding. Suitable for a wide range ...
Description:
Multi-tapped secondary winding. Suitable for a wide range of applications requiring selected secondary voltages. Double section bobbin constructionFully shrouded bobbinsFull varnish impregnationMulti-hole frame fixingSolder tag terminations100% electrical and flash testedTested in accordance with BS3535 and EN 60 742.
Thermal fuse in primary providing overload and short ...
Description:
Thermal fuse in primary providing overload and short circuit protectionFlame retardant materials to UL94-V0Fully shrouded windingsExtra pins for secure board mountingDesigned and tested in accordance with EN 61558 (EN 60742) EN 60950.
Fully shrouded bobbinsExtra pins for secure board mounting100% ...
Description:
Fully shrouded bobbinsExtra pins for secure board mounting100% electrical and flash testedTested in accordance with BS3535 and EN 60 742.
Twin 115Va.c. 50 to 60Hz primary windings for ...
Description:
Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connectionTwin secondary windings for series or parallel connectionLow profile compact designVacuum epoxy resin moulded to UL94-V0 ratingDouble section glass fibre reinforced polyamide bobbins100% electrical and flash testedLow inter-winding ...