Seaward PrimeTest 250 UK PAT Tester, Class I, Class II Test Type

  • RS Stock No. 706-6921
  • Mfr. Part No. 392A910
  • Manufacturer Seaward
Technical data sheets
Legislation and Compliance
RoHS Status: Exempt
COO (Country of Origin): GB
Product Details

Seaward Primetest 250

Lightweight, battery powered manual PAT tester
Performs all the tests required by the IEE Code of Practice for the In-Service Inspection and Testing of Electrical Equipment
Automatic test sequences with clear PASS /FAIL indication
Tests Class I, Class II equipment, IEC leads extension leads and RCDs
200mA earth bond testing
250V and 500V insulation testing suitable for testing sensitive electrical appliances and surge protected leads.
Equivalent leakage (using battery power) and protective conductor/ touch current test (using manis power)
Selectable protective conductor current PASS limits to accomodate filtered mains equipment
Portable RCD trip time test (RCD adaptor required)
3 phase differential leakage test ( 3 phase adaptor required)
Input voltage range 225 – 254V ac 13A max

Supplied with

Soft carry case, earth bond lead, short red lead (IEC to BS1363 UK mains plug), evaluation CD, instructions & 6 x non rechargeable AA alkaline batteries

Specifications
Attribute Value
Tester Type Pass/Fail PAT
Test Type Class I, Class II
Testing Method Automatic, Manual
Power Source Battery, Mains
Maximum Supply Voltage 254V ac
Plug Type Type G - British 3-pin
Model Number p PrimeTest 250 UK
Minimum Supply Voltage 225V ac
23 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 2,534.36
units
Per unit
1 +
MYR2,534.36
Related Products
The PROFITEST MXTRA Starter Pack Kit consists of ...
Description:
The PROFITEST MXTRA Starter Pack Kit consists of the M520P test insrument along with a VARIO plug adapter set, F2000 universal carrying pouch, rechargeable battery pack and battery charger. Loop and line impedance measurement Measurement of insulation resistance using nominal ...
The DT-500 checks insulation resistance for systems or ...
Description:
The DT-500 checks insulation resistance for systems or devices.A 500 V measuring voltage delivered by the device is used to perform this check (in compliance with NF C15-100).Phase / neutral shunt function.Battery-saving function.Live voltage indicator and battery status indicator.Belt clip ...
LTDV-suitable for use with EasyPAT, MicroPAT, PAC1500xi, PAT1900xi, ...
Description:
LTDV-suitable for use with EasyPAT, MicroPAT, PAC1500xi, PAT1900xi, PAT2100xi, PAT500H, MPAT40, MPAT60, Megger PAT4, Robin PATs and all Edgcumbe (Metrohm PATs)LTDVR-suitable for use with Seaward PAT2000iee, Seaward PAT 2000, PAT1000s, PAT2000, IT1000, PAT1000x, Supernova, Europa, Europa PAC and Megger PATs ...
PAT450 additional features:. Electrical equipment safety testing in ...
Description:
PAT450 additional features:. Electrical equipment safety testing in accordance with DIN VDE 0701-0702Fully configurable for fast testing and high productivity250V and 500V insulation tests and 200mA continuity testDifferential, substitute or touch leakage current tests with 10 μA resolutionLarge 5.7in. VGA ...