- RS Stock No.:
- 123-3557
- Manufacturer:
- RS PRO
Discontinued product
- RS Stock No.:
- 123-3557
- Manufacturer:
- RS PRO
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- CN
Product Details
RS Pro ISR-6051 Analog Oscilloscope
As a traditional analog oscilloscope, RS Pro ISR-6051 can immediately represent a waveform on its 6 inch CRT display. The benefit is a faster update rate. A digital storage oscilloscope needs to digitally sample a signal before that signal can be displayed. An analog oscilloscope displays the signal in real-time, with less risk of modifying any part of the original signal. Its ability to measure waveform intensity makes the analog oscilloscope an instrument of choice in some fields e.g. TV and video. The RS Pro ISR-6051 has a built-in 6-digit frequency counter, cursor and numerical readouts, making waveform observation and measurement fast and accurate. Setup save/recall enable regular setups to be recalled for ease-of-use and for production test applications.
Rise time 7/ 50 ns
8 x 10 1 cm divisions
Cursor readout measurement of ΔV, ΔT, 1/ΔT
50 Hz to 50 MHz frequency counter, 6-digits, accuracy ±0.01%
MEM save/recall of up to 10 front panel setups
TV sync triggering for automatic linear focus maintains optimum beam focus
Variable trigger hold off for stable display of periodic waveforms
ALT MAG functions (x5, x10, x20)
Trigger modes Auto, Norm, TV field and TV line
Sensitivity 1 mV to 20 V/div in 14 steps
Timebase 0.2 μs to 0.5 sec/div in 20 steps
400 V (dc + ac peak) maximum input to CH1 and CH2
Constructed to EN61010-1 (safety standard) 300V Cat II
8 x 10 1 cm divisions
Cursor readout measurement of ΔV, ΔT, 1/ΔT
50 Hz to 50 MHz frequency counter, 6-digits, accuracy ±0.01%
MEM save/recall of up to 10 front panel setups
TV sync triggering for automatic linear focus maintains optimum beam focus
Variable trigger hold off for stable display of periodic waveforms
ALT MAG functions (x5, x10, x20)
Trigger modes Auto, Norm, TV field and TV line
Sensitivity 1 mV to 20 V/div in 14 steps
Timebase 0.2 μs to 0.5 sec/div in 20 steps
400 V (dc + ac peak) maximum input to CH1 and CH2
Constructed to EN61010-1 (safety standard) 300V Cat II
Supplied with
Mains lead, instruction manual
RS PRO Oscilloscope
The RS PRO 50MHz analogue oscilloscope has a built-in 6-digit frequency counter, cursor and numerical readouts, making waveform observation and measurement fast and accurate. It has 2 analogue channels. Set-up saves/recall enable regular set-up to be recalled for ease-of-use and production test applications. Elusive signal details can be revealed using the ALTMAG function to magnify signals (x5, x10x 30).
A digital storage oscilloscope needs to digitally sample a signal before that signal can be displayed. An analogue oscilloscope displays the signal in real-time, with less risk of modifying any part of the original signal. Its ability to measure waveform intensity makes the analogue oscilloscope an instrument of choice in some fields e. G. TV and video.
A digital storage oscilloscope needs to digitally sample a signal before that signal can be displayed. An analogue oscilloscope displays the signal in real-time, with less risk of modifying any part of the original signal. Its ability to measure waveform intensity makes the analogue oscilloscope an instrument of choice in some fields e. G. TV and video.
Features and Benefits
400V (dc + ac peak) maximum input to CH1 and CH2
8 x 10 1cm divisions
Bandwidth is 50MHz
Constructed to EN61010-1 (safety standard) 300V Cat II
Cursor readout measurement of ΔV, ΔT, 1/ΔT
Rise time 7/ 50ns
Sensitivity 1mV to 20V/div in 14 steps
Timebase 0.2μs to 0.5 sec/div in 20 steps
Trigger modes Auto, Norm, TV field and TV line
TV sync triggering for automatic linear focus maintains optimum beam focus
Variable trigger hold off for stable display of periodic waveforms
8 x 10 1cm divisions
Bandwidth is 50MHz
Constructed to EN61010-1 (safety standard) 300V Cat II
Cursor readout measurement of ΔV, ΔT, 1/ΔT
Rise time 7/ 50ns
Sensitivity 1mV to 20V/div in 14 steps
Timebase 0.2μs to 0.5 sec/div in 20 steps
Trigger modes Auto, Norm, TV field and TV line
TV sync triggering for automatic linear focus maintains optimum beam focus
Variable trigger hold off for stable display of periodic waveforms
Applications
Audio and video recording equipment
Designing
Research & Development
Testing in manufacturing
Testing of signals voltage in radio broadcasting equipment
Testing signal voltage in-circuit debugging
Designing
Research & Development
Testing in manufacturing
Testing of signals voltage in radio broadcasting equipment
Testing signal voltage in-circuit debugging
Certifications
ANSI/ESD S20.20:2014
BS EN 61340-5-1:2007 standards.
BS EN 61340-5-1:2007 standards.
RS Pro
Specifications
Attribute | Value |
---|---|
Bandwidth | 50MHz |
Number of Analogue Channels | 2 |
Oscilloscope Type | Analogue |
Power Source | Mains |
Display Type | LCD |
Minimum Vertical Sensitivity | 1mV/div |
Maximum Vertical Sensitivity | 20V/div |
Minimum Time Base | 0.2µs/div |
Length | 370mm |
Maximum Time Base | 0.5s/div |
Weight | 7.2kg |
Input Impedance | 1 MΩ |
Dimensions | 370 x 275 x 130mm |
Height | 130mm |
Input Capacitance | 25 pF |
Rise Time | 50 ns @ 2 mV/div, 7 ns @ 20 V/div |
Safety Category Level | CAT I, CAT II, CAT III, CAT IV |