Metrix MTX 1032-C Oscilloscope Probe, Probe Type: Differential 50MHz

  • RS Stock No. 512-5025
  • Mfr. Part No. MTX1032-C
  • Manufacturer Metrix
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

30 & 50 MHz differential probes for MX 9030-Z, MTX 1032-B and MTX 1032-C oscilloscopes

An indispensable accessory for analogue or digital oscilloscopes to visualise signals that are not referenced to the ground!
A range of three models to fulfil different requirements.
1 or 2 input channels.
Coaxial or banana measuring leads/long length banana leads.
A model with coaxial inputs that can be used with oscilloscope probes.
30 MHz or 50 MHz bandwidth.
Mains or battery power (depending on model).
Presented in laboratory casing or handheld probe with wrist strap.
Input voltage differential range of ±0.1 → ±600 V (depending on model).
Meets standards up to 600 V - CAT IV (depending on model).
Compatible with all types of class 1 oscilloscope.
Mechanical compatibility with oscilloscopes from the MTX family.
Conforms to DBT safety standards in accordance with IEC 61010-1 (2001).
Conforms to CEM standards in accordance with NF EN 61326-1 (07/97) + A1 (10/98) + A2 (2001).

Specifications
Attribute Value
Probe Type Differential
Attenuation 1:10, 1:100
Bandwidth 50MHz
Connector Type BNC
Model Number p MTX 1032-C
Number of Probes 7
Safety Category Level CAT II
Safety Category Voltage 600V
Safety Category CAT II 600 V
Rise Time 7ns
3 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 3,540.70
units
Per unit
1 +
MYR3,540.70
Related Products
Bandwidth DC-70 MHzRise time ≤5 nsDC accuracy ±2%Attenuation ...
Description:
Bandwidth DC-70 MHzRise time ≤5 nsDC accuracy ±2%Attenuation ratio 50 X/500 XMaximum differential test voltage (DC + Peak AC) 50 X: 150 V, 500 X: 1500 VMaximum input common mode voltage (voltage-to-earth Vrms) 600 V CATIII, 1000 V CATIIInput impedance ...
Bandwidth 500 MHzProbe Ratio 10:1Cable Length 1.2 metersInput ...
Description:
Bandwidth 500 MHzProbe Ratio 10:1Cable Length 1.2 metersInput Impedance 10 MOhmCapacitance 12 pFApprox. Rise Time 3 nsMax. Voltage 1000 V CAT III / 600 V CAT IVCompensation Range 10 to 22 pFSafety Rating 1000 V CAT III / 600 V ...
Rated voltage of probe:. Highly flexible 1.2m coaxial ...
Description:
Rated voltage of probe:. Highly flexible 1.2m coaxial cable with BNC plugCompensation adjusting screwø 2 mm safety socket for reference connectionIsoprobe® II 10:1 450MHz probePush-on hook clip with additional reference lead (600 V, CAT II)Push-on BNC plug (500 V, CAT ...
Tektronix high voltage probing solutions offer safety and ...
Description:
Tektronix high voltage probing solutions offer safety and accuracy in applications which include: floating measurements; switching power supply design; motor drive design; electronic ballast design; CRT display design; power converter design and service; power device evaluation. Overrange indicatorSafety ...