1 Pole Panel Mount Non Fused Isolator Switch, 10 A

  • RS Stock No. 416-708
  • Mfr. Part No. AF1X0038031F2D
  • Manufacturer Carlingswitch
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): MX
Product Details

Single Pole, Hydraulically Damped

Insulation Resistance >100MΩ
The convenience of on/off switching and overcurrent protection in one package
Visual indication of breaker state via the unique, single shot moulded, two colour actuator rocker (black and red)
Temperature stable. Will not trip due to high ambient temperature levels
Trip free mechanism making it impossible to hold the breaker contacts closed during an overcurrent or short circuit fault
Low contact resistance (typically < 0·1Ω)
Terminal connections via 1/4in push-on receptacles
Mounting hole size: 32 x 19mm
Fixing holes: 4mm Ø 42mm centres
Full arc suppression allowing extended contact life
IEC Classification S/HM

Approvals

UL, CSA, VDE

Thermal Magnetic Convertible

All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).

Specifications
Attribute Value
Number of Poles 1
Maximum Current 10 A
Mounting Type Panel Mount
Voltage Rating 65 V dc, 250 V ac
Switch Rating 10 A
Length 54.76mm
Width 19.18mm
Depth 61.43mm
Terminal Type Push In
253 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 97.42
units
Per unit
1 - 9
MYR97.42
10 - 24
MYR96.58
25 - 49
MYR89.48
50 - 99
MYR85.11
100 +
MYR74.99
Related Products
Perform isolation and switching with positive contact indication ...
Description:
Perform isolation and switching with positive contact indication of the electrical distribution circuits.They are used as inlet switches on the modular distribution board, on the PLC box and cabinet or on the local box for local control of motor circuits, ...
All have a nominal voltage of 690V. The ...
Description:
All have a nominal voltage of 690V. The stated motor rating utilisation category AC23A/AC3 is for 3 phase 380/440V supply. Padlockable (x4) in "OFF" positionFingerproof main terminals on 20A to 63A switchesTerminal shrouds supplied with 80A to 250A switches.
High impact polycarbonate enclosures to IP65Lockable with up ...
Description:
High impact polycarbonate enclosures to IP65Lockable with up to four padlocks in the OFF positionVersions available with N/O early break auxiliary contactsEarth terminal provided, neutral terminal not includedAux. contact not feasible in 3 pole units160A unit fitted with terminal lugs ...
Siemens 3RV1 circuit breakers have three main contact ...
Description:
Siemens 3RV1 circuit breakers have three main contact elements. In order to achieve maximum flexibility, signaling switches, auxiliary switches and isolator modules can be easily fitted to the switches without the use of any tools according to requirements. Time saving: ...