Schneider Electric C60 MCB Mini Circuit Breaker 2P, 10 A, 10 kA rms @ 125 V dc, 20 kA rms @ 240 V ac, Curve C

Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): FR
Product Details

Schneider Electric Multi 9 C60N MCBs C Curve

C60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents. Fully compliant with standards /EN 60947-2. Tripping curve type C that trips instantly at a rate of five to ten times its rated current. Multi 9 supplementary protectors and miniature circuit breakers limit let-through current, providing faster separation of the component from the fault, thereby reducing system damage. Reverse feeding of line power is permitted. Trip-free mechanism: Contacts cannot be held in the ON position when the C60 circuit breaker is tripped automatically.

Benefits and Features

Small Compact size
Easy installation on DIN rails
Limits let thru current.
Insulated terminals (IP20)
World-Wide Availability—The Multi 9 products are available and supported throughout the world by Schneider Electric.

Standards

IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCB’s ) and also air circuit breakers (ACB’s).

Q: What is tripping Curve C

Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications

Merlin Gerin – MCBs

Miniature Circuit Breakers; Contact Position indicated by switch levers

Specifications
Attribute Value
Series C60
Number of Poles 2
Current Rating 10 A
Tripping Characteristics Type C
Rated AC Voltage 120 240 V
Rated DC Voltage 125V
Breaking Capacity 20 kA
Length 107mm
Width 36mm
Depth 78.5mm
Temporarily out of stock - back order for despatch when stock is available
Price Each
MYR 517.20
units
Per unit
1 +
MYR517.20
Related Products
Miniature Circuit Breakers; Contact Position indicated by switch ...
Description:
Miniature Circuit Breakers; Contact Position indicated by switch levers. B, C and D curveVisisafe green strip indicates and guarantees the safe position of contactsVisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and re-closing loads ...
iC60H curve B, C, D circuit breakers are ...
Description:
iC60H curve B, C, D circuit breakers are multi-standard circuit breakers which combine circuit protection against short-circuit currents and circuit protection against overload currents. VisiSafe guarantees the downstream circuit is always safe, regardless of overvoltage conditions, wear, or operator experience ...
Circuit breaker to protect photovoltaic modules against fire ...
Description:
Circuit breaker to protect photovoltaic modules against fire in case of short-circuits. Insulation voltage Ui = 1000 VMax. operating voltage Ue = 800 V DCRatings: From 1A to 25A.
iDPN is a neutral breaking miniature circuit breaker ...
Description:
iDPN is a neutral breaking miniature circuit breaker used to protect the wires and equipments in the circuit. VisiSafe for safe operation and maintenance work on circuitsVisi-Trip detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention timeClass-2 insulation.