![]() RoHS Certificate of Compliance EU Directives 2011/65/EU and 2015/863 restrict the use of the 10 substances below in the manufacture of specified types of electrical equipment. The restricted substances and maximum allowed concentrations in the homogenous material are, by weight:Whilst this restriction does not legally apply to components, it is recognised that component “compliance” is relevant to many customers. RS definition of RoHS Compliance:
The supplier of the item listed below has informed RS Components that the product is “RoHS Compliant”. RS Components has taken all reasonable steps to confirm this statement. Information relates only to products sold on or after the date of this certificate. Compliant product details |
|||||||||||||||||||||||
Order Code | 780-0282 | ||||||||||||||||||||||
Description | Flow Switch Cynergy3 FSVPLC | ||||||||||||||||||||||
Manufacturer/Brand Name | Cynergy3 | ||||||||||||||||||||||
Manufacturer Part No. | FSVPLC30 | ||||||||||||||||||||||
780-0282 | |
Flow Switch Cynergy3 FSVPLC | |
Cynergy3 | |
FSVPLC30 |
Date | Dec 8, 2019 |
The FSVPLC can be used to control some other equipment or process via a PLC. If used in a pumped system, the device has to be fitted in the pipe above the pump. The FSVPLC gives a closed contact signal to the PLC once the flow rate exceeds 0.6 L/min or 3.0 L/min, depending on version.
Signal level output to PLC
0.6 L/min or 3.0 L/min turn on flow rate
Automatic shut down on flow stop
G1"" pipe connection
Attribute | Value |
---|---|
Media Monitored | Liquid |
Device Type | In-line |
Maximum Flow Rate | 80 L/min |
Supply Voltage | 5 V ac |
Pipe Diameter Range | G1 |
Connection Type | 1 BSP Female |
Maximum Pressure | 8bar |
Material | Brass |
Maximum Media Temperature | +85°C |
Maximum Operating Temperature | +85°C |
Series | FSVPLC |