Lapp 4 Core 1 mm² Mains Power Cable, Black Rubber Sheath 100m, 15 A 500 V, 318TRS H05RR-F

  • RS Stock No. 406-962
  • Mfr. Part No. 16002113
  • Manufacturer Lapp
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

H05RR-F Flexible Rubber Cable

A tough, lightweight rubber sheathed cable that is suitable for use with hand held devices such as kitchen and office appliances that meets H05RR-F harmonised code specification.


Features and Benefits

Rubber insulation and sheath Lightweight and flexible
Cold resistant
Voltage Rating 300/500 V

Note

The number of strands used in the construction of the cores is nominal and may vary.

Specifications
Attribute Value
Number of Cores 4
Cross Sectional Area 1 mm²
Sheath Colour Black
Current Rating 15 A
Length 100m
Voltage Rating 500 V
Outer Diameter 9.3mm
Sheath Material Rubber
Type 318TRS
Minimum Operating Temperature -25°C
Maximum Operating Temperature +60°C
Conductor Strand Type Stranded
Harmonised Code H05RR-F
Conductor Material Copper
Core Strands 32/0.2 mm
Insulation Material Rubber
Conductor Resistance 19.5 Ω/km
Number of Strands 32
American Wire Gauge 17 AWG
Standards Met CE
Size of Strands 0.2 mm
Temporarily out of stock - back order for despatch 05/06/2020, delivery within 4 working days from despatch date
Price 1 Reel of 100 Metre(s)
MYR 1,000.48
Reel(s)
Per Reel
Per Metre*
1 +
MYR1,000.48
MYR10.005
*price indicative
Related Products
RS Pro fire-resistant cables are designed for security ...
Description:
RS Pro fire-resistant cables are designed for security circuit power supplies which continue to operate in the event of disasters. Applications include: Lighting, security and lifts. Bare copper conductorOrange outer sheathSilicone rubber insulationFire resistantHalogen freeRoHS.
Lapp NYM-J standard wiring and installation cable that ...
Description:
Lapp NYM-J standard wiring and installation cable that is designed for use in plaster, brickwork and concete. Bare copper conductorsPVC-based wire insulationPVC-based outer sheathAbove, below, flush and recess routingSuitable for dry, damp and wet room applicationsSuitable for outdoor use if ...
PVC cables designed for use in fixed installation ...
Description:
PVC cables designed for use in fixed installation in dry or damp rooms and outdoors, underground or direct burial in concrete. PVC outer sheath Designed in accordance to VDE 0276-603 Nominal voltage 600/1000 V Test voltage 4000 V ac Temperature ...
This H07ZZ-F harmonised cable is manufactured with a ...
Description:
This H07ZZ-F harmonised cable is manufactured with a low smoke zero halogen (LSZH) sheath. It is installed where fire, smoke emission and toxic fumes create potential threats to life and equipment. Applications include supplying mobile power units, UPS installations, stage ...