Legrand 40VA DIN Rail Transformer, 215V ac, 230V ac, 245V ac, 385V ac, 400V ac, 415V ac Primary 2 x, 24V ac Secondary

  • RS Stock No. 535-7711
  • Mfr. Part No. 0 442 31
  • Manufacturer Legrand
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): FR
Product Details

Control Transformers

Safety isolating transformer single phase
DIN rail mount (up to 250VA) or Surface mount with screws (400VA & above)
Terminals with finger protection IP2x or xxB up to 400VA
New design provides interference filter between windings
Clear laser engraved markings
Suitable for maximum 50°C ambient, without de-rating

Standards

IEC 61-558-2-2 and 2-4 or 2-6

Supplied with

0V/earth connection link

Approvals

UL506, CSA

Specifications
Attribute Value
Primary Voltage Rating 215V ac, 230V ac, 245V ac, 385V ac, 400V ac, 415V ac
Secondary Voltage Rating 24V ac
Power Rating 40VA
Mounting Type DIN Rail
Number of Outputs 2
Width 94mm
Depth 78mm
Dimensions 113 x 94 x 78mm
Maximum Temperature +50°C
Weight 1.2kg
37 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 320.86
units
Per unit
1 - 9
MYR320.86
10 - 24
MYR308.55
25 - 49
MYR301.94
50 - 99
MYR295.27
100 +
MYR287.88
Related Products
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applicationsLow loss noise laminationsDual standard primary winding 230 / 400Vac with +15V tap for input flexibilityDual secondaries are centre tapped. Earth terminal providedVarnish impregnated for overall ...
Safety isolating and isolating control transformersTwin secondary winding ...
Description:
Safety isolating and isolating control transformersTwin secondary winding for series or parallel connection63,100,160 and 250VA transformers can be mounted on standard 35mm DIN railAll units have 4 hole panel mount fixingsEasy installation 4mm² cage clamp terminalsInsulation catagory Class B.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.