Block 500VA DIN Rail Transformer, 230V ac, 400V ac Primary 2 x, ±110V ac, ±120V ac, ±55V ac, ±60V ac Secondary

  • RS Stock No. 310-1730
  • Mfr. Part No. MIT/I/500
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Isolating Transformers : 0-230-400Vac Primary, 2x60-55-0-55-60Vac Secondary, DIN Mount

High quality multi-purpose isolating transformers suitable for a wide range of applications requiring selected secondary voltages.

Panel mounting via the fixing holes
Optional DIN rail mounting bracket for standard 35mm DIN rail (63 to 250VA units)
Fully shrouded screw and push-on crimp terminals with permanent marking
High efficiency, low regulation
Double reinforced insulation E (UL class 105)
4kV flash tested primary/secondary
Impregnated for protection against humidity
Insulation catagory Class E

Standards

EN61558

Approvals

VDE, UL recognised for Canada UL recognised

Approvals

VDE; UL

Standards

EN61558

Specifications
Attribute Value
Primary Voltage Rating 230V ac, 400V ac
Secondary Voltage Rating ±110V ac, ±120V ac, ±55V ac, ±60V ac
Power Rating 500VA
Mounting Type Chassis
Number of Outputs 2
Length 111mm
Width 148mm
Depth 150mm
Dimensions 111 x 148 x 150mm
Maximum Temperature +40°C
Weight 8kg
11 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 667.56
units
Per unit
1 - 9
MYR667.56
10 - 24
MYR617.77
25 - 49
MYR588.48
50 - 99
MYR578.41
100 +
MYR564.29
Related Products
This series of control transformers stands out thanks ...
Description:
This series of control transformers stands out thanks to the following special features:. Low voltage dropHigh performance during short-term operationInternational standard voltage 230 V/400 V in accordance with DIN IEC 38Primary-side ±5% taps to adjust the voltageCan be used worldwide ...
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Safety isolating transformer single phaseDIN rail mount (up ...
Description:
Safety isolating transformer single phaseDIN rail mount (up to 250VA) or Surface mount with screws (400VA & above) Terminals with finger protection IP2x or xxB up to 400VANew design provides interference filter between windingsClear laser engraved markingsSuitable for maximum 50°C ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads.Only the pins indicated on the wiring diagram "physically" exist.