Chauvin Arnoux CA1631 Current & Voltage Calibrator 0 → 24 mA

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631

These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.

Instruments for use in developing and verifying measurement chains
CA1621 temperature calibrator for J,K,T,E,R,S,B,N thermocouples and voltage in mV
CA1623 temperature calibrator for Pt10,Pt50,Pt100,Pt200,Pt500,Pt1000 and Pt1000(JIS) probes and resistance
CA1631 current loop calibrator for measuring and supplying DC current loop 0 to 24mA, dc voltage between 0 and 20V
Calibrator dimensions 205 x 97 x 45mm
Calibrator weight 472g (including batteries)

Supplied with

Test wires (2 pairs), crocodile clip, 6AAA 1.5V batteries (6), operating manual in 5 languages, carrying case

Specifications
Attribute Value
Absolute Maximum Voltage Measurement 20V dc
Absolute Maximum Current Measurement 24mA
Best Accuracy ±0.015 %
Power Source Battery, Mains
Battery Type AAA
Dimensions 205 x 98 x 46mm
Weight 472g
Maximum Operating Temperature +55°C
Maximum Source Current 24mA
Minimum Operating Temperature -10°C
Maximum Source Voltage 0 mA, 20 V
Model Number p CA1631
Minimum Source Voltage 0V
4 Within 4 working day(s) (Global stock)
8 Within 4 working day(s) (Global stock)
Price Each
MYR 3,917.19
units
Per unit
1 +
MYR3,917.19
Related Products
An easy to use, portable instrument for general ...
Description:
An easy to use, portable instrument for general purpose signal injection which does not require any standardisation before use. 3 voltage and 2 current ranges1kΩ precision resistor (0.01%) is supplied to provide an extended voltage range of 0 to 8VRequires ...
A highly accurate millivolt source which requires no ...
Description:
A highly accurate millivolt source which requires no standardisation before use. Provides 1mV to 999.9mV in 3 rangesShort circuit and overload protectedRequires 6 x AA alkaline batteries.
A portable, high stability, instrument deriving its accuracy ...
Description:
A portable, high stability, instrument deriving its accuracy from a precision aged reference diode and low temperature coefficient metal film resistors. The instrument incorporates overload protection and LED indication of insufficient drive voltage. A Null measuring facility allows dc current ...
A pocket size instrument with an accuracy of ...
Description:
A pocket size instrument with an accuracy of 0.05% that can source and measure voltage and current in one compact unit. Three voltage and 3 current rangesSource output and measurement values displayed on clear LCDHoused in rugged ABS caseLow battery ...