LEM HX Series Open Loop Current Sensor, ±9A

  • RS Stock No. 435-8684
  • Mfr. Part No. HX 03-P/SP2
  • Manufacturer LEM
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

HX - P/SP2 Series

Open Loop Hall Effect current transducers with integral primary connections for the accurate measurement of current.

Open Loop (low power consumption)
AC,DC, and mixed signal measurement
Extended measuring range (3xlpn)
Small size
HX 03-20 (23.5x15.8x19mm)
HX 25-50 (20x19x15.4mm)
Multi turn Primary
Unipolar power supply
Operating Temperature Range -25 to +85°C
Supply voltage 12/14Vdc
Load Resistance 2KΩ
Insulation test voltage 3kV
Frequency Bandwidth 50kHz
Body Mat'l UL94-V0
Weight 8g

Specifications
Attribute Value
Sensor Technology Open Loop
Nominal Current ±9A
Supply Voltage 12 15 V
Sensor Type Hall Effect
Mounting Type PCB Mount
Frequency Bandwidth 50 kHz
Accuracy ±1 %
Bore Size 0.6mm
Minimum Operating Temperature -25°C
Series HX
Maximum Operating Temperature +85°C
Depth 15.4mm
Height 20.5mm
Width 19mm
79 In Global stock for delivery within 4 - 6 working days
Price Each
MYR 67.23
units
Per unit
1 - 14
MYR67.23
15 - 24
MYR63.30
25 +
MYR61.82
Related Products
Linear current sensors from Honeywell incorporating LOHET II ...
Description:
Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers. These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% ...
ATO series is a split core current transformer ...
Description:
ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement).ATO series is an ideal current transformer for new Smart-Grid applications. Split-core ...
The LEM transformer is a split core current ...
Description:
The LEM transformer is a split core current transformer with high accuracy and low phase shift. ATO series is ideal for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the secondary circuit ...
Measurement of dc currentsLarge apertureEasy panel mountingNo insertion ...
Description:
Measurement of dc currentsLarge apertureEasy panel mountingNo insertion lossesSupply voltage 20/50Vdc - 22/38VacAccuracy ±1%Size (HxWxD) 57.2 x 30 x 89.7mmOperating Temperature -20 → +50°CWeight 100g.